{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-33494 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-33494 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-33494 is a medium-severity missing authorization vulnerability in Siemens SIMATIC RTLS Locating Manager, published on 14 May 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-33494 and fix it if it is affected.\n\nWhat it is: CVE-2024-33494 is a medium-severity missing authorization vulnerability in Siemens SIMATIC RTLS Locating Manager, published on 14 May 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-33494 in the wild and no public exploit code.\n\nAffected product: Siemens SIMATIC RTLS Locating Manager. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-33494/ (Markdown: https://insights.sbomify.com/CVE-2024-33494/index.md)","id":"CVE-2024-33494","markdown":"https://insights.sbomify.com/CVE-2024-33494/index.md","name":"CVE-2024-33494","record":{"aliases":["GHSA-3m87-c3q9-vxf8"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["denial_of_service","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"RTLS Locating Manager","requires_auth":"none","summary":"Unauthenticated attackers can disrupt secondary RTLS systems and cause data loss by sending unverified heartbeat messages.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":6.9,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-345","name":"Insufficient Verification of Data Authenticity"}],"description":"A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions \u003c V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions \u003c V3.0.1.1). Affected components do not properly authenticate heartbeat messages. This could allow an unauthenticated remote attacker to affected the availability of secondary RTLS systems configured using a TeeRevProxy service and potentially cause loss of data generated during the time the attack is ongoing.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in SIMATIC RTLS Locating Manager","id":"CVE-2024-33494","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Denial of service in SIMATIC RTLS Locating Manager","id":"CVE-2024-33495"},"packages":[],"prev":{"headline":"Memory corruption in Solid Edge","id":"CVE-2024-33493"},"products":["SIMATIC RTLS Locating Manager"],"published":"2024-05-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-02","vendors":["Siemens"]},"summary":"Unauthenticated attackers can disrupt secondary RTLS systems and cause data loss by sending unverified heartbeat messages.","url":"https://insights.sbomify.com/CVE-2024-33494/"}