{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-33606 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-33606 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-33606 is a high-severity missing authorization vulnerability in MicroDicom DICOM Viewer, published on 11 Jun 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2024-33606 and fix it if it is affected.\n\nWhat it is: CVE-2024-33606 is a high-severity missing authorization vulnerability in MicroDicom DICOM Viewer, published on 11 Jun 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2024-33606 in the wild and no public exploit code.\n\nAffected product: MicroDicom DICOM Viewer. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-33606/ (Markdown: https://insights.sbomify.com/CVE-2024-33606/index.md)","id":"CVE-2024-33606","markdown":"https://insights.sbomify.com/CVE-2024-33606/index.md","name":"CVE-2024-33606","record":{"aliases":["GHSA-jggq-6mpj-9v53"],"analysis":{"component_type":"desktop_application","fix_type":"no_fix_stated","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Medical imaging viewer","requires_auth":"none","summary":"Attackers can read or overwrite medical images via a custom URL scheme, requiring user interaction to exploit.","user_interaction":"required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"dicom_viewer","vendor":"microdicom"}],"cvss":{"score":8.6,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-862","name":"Missing Authorization"},{"id":"CWE-939","name":"Improper Authorization in Handler for Custom URL Scheme"}],"description":"An attacker could retrieve sensitive files (medical images) as well as plant new medical images or overwrite existing medical images on a MicroDicom DICOM Viewer system. User interaction is required to exploit this vulnerability.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"MicroDicom DICOM Viewer Improper Authorization in Handler for Custom URL Scheme","id":"CVE-2024-33606","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in Intel(R) TDX module software","id":"CVE-2024-33607"},"packages":[],"prev":{"headline":"Path traversal in Multiple MFPs (multifunction printers)","id":"CVE-2024-33605"},"products":["DICOM Viewer"],"published":"2024-06-11","related":[{"cvss_score":8.7,"headline":"MicroDicom DICOM Viewer Stack-based Buffer Overflow","id":"CVE-2024-28877","kev_date_added":null,"published":"2024-06-11"},{"cvss_score":7.8,"headline":"MicroDicom DICOM Heap-based Buffer Overflow","id":"CVE-2024-22100","kev_date_added":null,"published":"2024-03-01"},{"cvss_score":7.8,"headline":"MicroDicom DICOM Viewer Out-of-Bounds Write","id":"CVE-2024-25578","kev_date_added":null,"published":"2024-03-01"},{"cvss_score":5.7,"headline":"MicroDicom DICOM Viewer Improper Certificate Validation","id":"CVE-2025-1002","kev_date_added":null,"published":"2025-02-10"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-08-02","vendors":["MicroDicom"]},"summary":"Attackers can read or overwrite medical images via a custom URL scheme, requiring user interaction to exploit.","url":"https://insights.sbomify.com/CVE-2024-33606/"}