# CVE-2024-3376: SourceCodester Computer Laboratory Management System config.php redirect

> Attackers can manipulate the URL argument in config.php to redirect users to malicious sites, potentially facilitating phishing or further attacks.

- **Severity:** High 7.3 (`CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L`)
- **Exploited in the wild:** Not known
- **Login needed:** Not needed
- **Attackable:** Over the internet
- **Victim action needed:** Not needed
- **Fix available:** No
- **Published:** 6 Apr 2024
- **Updated:** 26 Feb 2025
- **Also known as:** GHSA-574q-w5vp-7fm6

## What is CVE-2024-3376?

CVE-2024-3376 is a high-severity vulnerability in SourceCodester Computer Laboratory Management System, published on 6 Apr 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.

### Official description

A vulnerability classified as critical has been found in SourceCodester Computer Laboratory Management System 1.0. This affects an unknown part of the file config.php. The manipulation of the argument url leads to execution after redirect. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-259497 was assigned to this vulnerability.

Weakness: CWE-670 (Always-Incorrect Control Flow Implementation), CWE-698 (Execution After Redirect (EAR))

## Which versions are affected by CVE-2024-3376?

It affects 1 product.


Products: Oretnom23 Computer Laboratory Management System.

## How do I fix CVE-2024-3376?

No fix has been published for CVE-2024-3376 yet. Limit exposure of the affected software until one is available.

## Is CVE-2024-3376 being exploited?

It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-3376 exists.

## Other vulnerabilities in SourceCodester Computer Laboratory Management System

- [CVE-2024-34479](https://insights.sbomify.com/CVE-2024-34479/): SQL injection in n/a (critical 9.8)
- [CVE-2024-34480](https://insights.sbomify.com/CVE-2024-34480/): SQL injection in n/a (critical 9.8)
- [CVE-2024-31546](https://insights.sbomify.com/CVE-2024-31546/): SQL injection in n/a (critical 9.8)
- [CVE-2024-31545](https://insights.sbomify.com/CVE-2024-31545/): SQL injection in n/a (critical 9.4)
- [CVE-2024-31547](https://insights.sbomify.com/CVE-2024-31547/): SQL injection in n/a (critical 9.1)

## Fix prompt for AI coding agents

```text
Check this codebase for CVE-2024-3376 and fix it if it is affected.

What it is: CVE-2024-3376 is a high-severity vulnerability in SourceCodester Computer Laboratory Management System, published on 6 Apr 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.
Exploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-3376 exists.

Affected product: SourceCodester Computer Laboratory Management System. No package-level version data is available, so check the vendor advisory linked from the reference page.

Task:
1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.
2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.
3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.
4. Run the tests and summarise what changed and why.
5. If nothing in the project is affected, say so and change nothing.

Reference: https://insights.sbomify.com/CVE-2024-3376/ (Markdown: https://insights.sbomify.com/CVE-2024-3376/index.md)
```

## Sources

- CVE record: https://www.cve.org/CVERecord?id=CVE-2024-3376
- NVD: https://nvd.nist.gov/vuln/detail/CVE-2024-3376
- OSV: https://osv.dev/vulnerability/CVE-2024-3376

---
From sbomify Insights: https://insights.sbomify.com/CVE-2024-3376/
Summaries are generated and may contain mistakes; the official description above is the record.
