{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-35294 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-35294 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-35294 is a medium-severity missing authorization vulnerability in Schneider Elektronik Series 700, published on 2 Oct 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2024-35294 and fix it if it is affected.\n\nWhat it is: CVE-2024-35294 is a medium-severity missing authorization vulnerability in Schneider Elektronik Series 700, published on 2 Oct 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2024-35294 in the wild and no public exploit code.\n\nAffected product: Schneider Elektronik Series 700. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-35294/ (Markdown: https://insights.sbomify.com/CVE-2024-35294/index.md)","id":"CVE-2024-35294","markdown":"https://insights.sbomify.com/CVE-2024-35294/index.md","name":"CVE-2024-35294","record":{"aliases":["GHSA-662h-8m8r-wfrp"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_read","account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"Schneider Elektronik Series 700","requires_auth":"none","summary":"Unauthenticated attackers can access the traffic capture function to steal plaintext administrative credentials from Schneider Elektronik Series 700 devices.","user_interaction":"required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"CERTVDE","cpe":[],"cvss":{"score":6.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"An unauthenticated remote attacker may use the devices traffic capture without authentication to grab plaintext administrative credentials.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Schneider Elektronik Series 700 prone to missing authentication for traffic capture function","id":"CVE-2024-35294","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Missing authorization in Perfect Harmony GH180","id":"CVE-2024-35295"},"packages":[],"prev":{"headline":"Schneider Elektronik Series 700 prone to missing authentication for critical reset function","id":"CVE-2024-35293"},"products":["Series 700"],"published":"2024-10-02","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-10-02","vendors":["Schneider Elektronik"]},"summary":"Unauthenticated attackers can access the traffic capture function to steal plaintext administrative credentials from Schneider Elektronik Series 700 devices.","url":"https://insights.sbomify.com/CVE-2024-35294/"}