{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-35522 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-35522 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-35522 is a high-severity command injection vulnerability in n/a, published on 11 Oct 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-35522 and fix it if it is affected.\n\nWhat it is: CVE-2024-35522 is a high-severity command injection vulnerability in n/a, published on 11 Oct 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-35522 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-35522/ (Markdown: https://insights.sbomify.com/CVE-2024-35522/index.md)","id":"CVE-2024-35522","markdown":"https://insights.sbomify.com/CVE-2024-35522/index.md","name":"CVE-2024-35522","record":{"aliases":["GHSA-r58v-99w5-7j3x"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"adjacent_or_local","non_default_config":true,"product_category":"Netgear WiFi Range Extender","requires_auth":"high_privilege","summary":"An authenticated attacker can execute arbitrary commands on Netgear EX3700 range extenders by manipulating specific parameters in the operating mode interface.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"ex3700_firmware","vendor":"netgear"}],"cvss":{"score":8.4,"severity":"high","source":"cna","vector":"CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N","version":"3.1"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"description":"Netgear EX3700 ' AC750 WiFi Range Extender Essentials Edition before 1.0.0.98 contains an authenticated command injection in operating_mode.cgi via the ap_mode parameter with ap_24g_manual set to 1 and ap_24g_manual_sec set to NotNone.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Command injection in n/a","id":"CVE-2024-35522","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in n/a","id":"CVE-2024-35526"},"packages":[],"prev":{"headline":"Command injection in n/a","id":"CVE-2024-35520"},"products":["n/a"],"published":"2024-10-11","related":[{"cvss_score":9.8,"headline":"Cross-site request forgery in n/a","id":"CVE-2021-32122","kev_date_added":null,"published":"2021-08-10"},{"cvss_score":8.8,"headline":"Misconfiguration in n/a","id":"CVE-2017-18747","kev_date_added":null,"published":"2020-04-23"},{"cvss_score":8.8,"headline":"Path traversal in n/a","id":"CVE-2017-18752","kev_date_added":null,"published":"2020-04-22"},{"cvss_score":8.8,"headline":"Auth bypass in n/a","id":"CVE-2017-18772","kev_date_added":null,"published":"2020-04-22"},{"cvss_score":8.7,"headline":"Netgear EX3700 mtd sub_41619C stack-based overflow","id":"CVE-2025-5934","kev_date_added":null,"published":"2025-06-10"},{"cvss_score":8.4,"headline":"Command injection in n/a","id":"CVE-2024-35519","kev_date_added":null,"published":"2024-10-14"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-03-13","vendors":["n/a"]},"summary":"An authenticated attacker can execute arbitrary commands on Netgear EX3700 range extenders by manipulating specific parameters in the operating mode interface.","url":"https://insights.sbomify.com/CVE-2024-35522/"}