{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-36266 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-36266 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-36266 is a high-severity authentication bypass vulnerability in Siemens PowerSys, published on 11 Jun 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-36266 and fix it if it is affected.\n\nWhat it is: CVE-2024-36266 is a high-severity authentication bypass vulnerability in Siemens PowerSys, published on 11 Jun 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-36266 in the wild and no public exploit code.\n\nAffected product: Siemens PowerSys. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-36266/ (Markdown: https://insights.sbomify.com/CVE-2024-36266/index.md)","id":"CVE-2024-36266","markdown":"https://insights.sbomify.com/CVE-2024-36266/index.md","name":"CVE-2024-36266","record":{"aliases":["GHSA-v3v4-h24m-3cr8"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["privilege_escalation","security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Siemens PowerSys","requires_auth":"none","summary":"A local attacker can bypass authentication in Siemens PowerSys to gain administrative privileges over managed remote devices.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"powersys","vendor":"siemens"}],"cvss":{"score":8.5,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:H/SI:H/SA:H","version":"4.0"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"}],"description":"A vulnerability has been identified in PowerSys (All versions \u003c V3.11). The affected application insufficiently protects responses to authentication requests. This could allow a local attacker to bypass authentication, thereby gaining administrative privileges for the managed remote devices.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in PowerSys","id":"CVE-2024-36266","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in Redmine DMSF Plugin","id":"CVE-2024-36267"},"packages":[],"prev":{"headline":"Apache Submarine Server Core: authorization bypass","id":"CVE-2024-36265"},"products":["PowerSys"],"published":"2024-06-11","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-08-02","vendors":["Siemens"]},"summary":"A local attacker can bypass authentication in Siemens PowerSys to gain administrative privileges over managed remote devices.","url":"https://insights.sbomify.com/CVE-2024-36266/"}