CVE-2024-36391 MileSight DeviceHub - CWE-320: Key Management Errors
Key management errors in MileSight DeviceHub allow authentication bypass and man-in-the-middle traffic interception.
- Exploited in the wild
- Not known
- Login needed
- Not needed
- Attackable
- Over the internet
- Victim action needed
- Not needed
- Fix
- None listed
What is CVE-2024-36391?
CVE-2024-36391 is a critical vulnerability in MileSight DeviceHub, published on 2 Jun 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.
Official description
MileSight DeviceHub - CWE-320: Key Management Errors may allow Authentication Bypass and Man-In-The-Middle Traffic
Weakness: CWE-320
Which versions are affected by CVE-2024-36391?
It affects 1 product.
Products include Milesight Devicehub.
How do I fix CVE-2024-36391?
No fix has been published for CVE-2024-36391 yet. Limit exposure of the affected software until one is available.
Is CVE-2024-36391 being exploited?
There is no known exploitation of CVE-2024-36391 in the wild and no public exploit code.
Other vulnerabilities in MileSight DeviceHub
- CVE-2024-36388 MileSight DeviceHub - CWE-305 Missing Authentication for Critical Function
- CVE-2024-27776 MileSight DeviceHub - CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
- CVE-2024-36389 MileSight DeviceHub - CWE-330 Use of Insufficiently Random Values
- CVE-2024-36390 MileSight DeviceHub - CWE-20 Improper Input Validation
- CVE-2024-36392 MileSight DeviceHub - CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Sources
Also known as GHSA-5h7p-2q7c-v7w8.