{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-36454 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-36454 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-36454 is a medium-severity denial of service vulnerability in Fsas Technologies Inc. IPCOM EX2 Series (V01L0x Series), published on 12 Jun 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-36454 and fix it if it is affected.\n\nWhat it is: CVE-2024-36454 is a medium-severity denial of service vulnerability in Fsas Technologies Inc. IPCOM EX2 Series (V01L0x Series), published on 12 Jun 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-36454 in the wild and no public exploit code.\n\nAffected product: Fsas Technologies Inc. IPCOM EX2 Series (V01L0x Series). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-36454/ (Markdown: https://insights.sbomify.com/CVE-2024-36454/index.md)","id":"CVE-2024-36454","markdown":"https://insights.sbomify.com/CVE-2024-36454/index.md","name":"CVE-2024-36454","record":{"aliases":["GHSA-v58c-6x2p-85gg"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"IPCOM network device","requires_auth":"none","summary":"Attackers can cause system reboot or suspension on IPCOM EX2 and VE2 series devices by sending specially crafted packets.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"jpcert","cpe":[],"cvss":{"score":5.3,"severity":"medium","source":"cisa-adp","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L","version":"3.1"},"cwes":[{"id":"CWE-908","name":"Use of Uninitialized Resource"}],"description":"Use of uninitialized resource issue exists in IPCOM EX2 Series (V01L0x Series) V01L07NF0201 and earlier, and IPCOM VE2 Series V01L07NF0201 and earlier. If this vulnerability is exploited, the system may be rebooted or suspended by receiving a specially crafted packet.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Denial of service in IPCOM EX2 Series (V01L0x Series)","id":"CVE-2024-36454","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2024"},"n_packages":0,"n_references":2,"next":{"headline":"Symantec Privileged Access Manager Remote Command Execution vulnerability","id":"CVE-2024-36455"},"packages":[],"prev":{"headline":"Cross-site scripting in Usermin","id":"CVE-2024-36453"},"products":["IPCOM EX2 Series (V01L0x Series)","IPCOM VE2 Series"],"published":"2024-06-12","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-02","vendors":["Fsas Technologies Inc."]},"summary":"Attackers can cause system reboot or suspension on IPCOM EX2 and VE2 series devices by sending specially crafted packets.","url":"https://insights.sbomify.com/CVE-2024-36454/"}