{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-37141 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-37141 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-37141 is a low-severity vulnerability in Dell Data Domain Operating System, published on 26 Jun 2024. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2024-37141 and fix it if it is affected.\n\nWhat it is: CVE-2024-37141 is a low-severity vulnerability in Dell Data Domain Operating System, published on 26 Jun 2024. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2024-37141 in the wild and no public exploit code.\n\nAffected product: Dell Data Domain Operating System. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-37141/ (Markdown: https://insights.sbomify.com/CVE-2024-37141/index.md)","id":"CVE-2024-37141","markdown":"https://insights.sbomify.com/CVE-2024-37141/index.md","name":"CVE-2024-37141","record":{"aliases":["GHSA-jx4w-2gqj-27r4"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Dell PowerProtect DD","requires_auth":"low_privilege","summary":"A remote low-privileged attacker can exploit an open redirect in Dell PowerProtect DD to cause information disclosure.","user_interaction":"required","vuln_class":"open_redirect"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"dell","cpe":[{"product":"data_domain_operating_system","vendor":"dell"}],"cvss":{"score":3.5,"severity":"low","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-601","name":"URL Redirection to Untrusted Site"}],"description":"Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an open redirect vulnerability. A remote low privileged attacker could potentially exploit this vulnerability, leading to information disclosure.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Open redirect in PowerProtect DD","id":"CVE-2024-37141","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"dell:data_domain_operating_system","products":["dell:data_domain_operating_system"],"type":"open_redirect","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in Dell Peripheral Manager","id":"CVE-2024-37142"},"packages":[],"prev":{"headline":"Command injection in PowerProtect DD","id":"CVE-2024-37140"},"products":["PowerProtect DD"],"published":"2024-06-26","related":[{"cvss_score":9.8,"headline":"Path traversal in PowerProtect Data Domain","id":"CVE-2026-53481","kev_date_added":null,"published":"2026-07-07"},{"cvss_score":9.8,"headline":"Auth bypass in PowerProtect Data Domain","id":"CVE-2026-53483","kev_date_added":null,"published":"2026-07-07"},{"cvss_score":9.8,"headline":"Auth bypass in PowerProtect Data Domain Feature Release","id":"CVE-2025-36594","kev_date_added":null,"published":"2025-08-04"},{"cvss_score":8.8,"headline":"Missing authorization in PowerProtect Data Domain","id":"CVE-2026-56086","kev_date_added":null,"published":"2026-07-08"},{"cvss_score":8.8,"headline":"Missing authorization in PowerProtect Data Domain","id":"CVE-2026-26944","kev_date_added":null,"published":"2026-04-20"},{"cvss_score":8.8,"headline":"Privilege escalation in DD OS 7.10","id":"CVE-2025-29987","kev_date_added":null,"published":"2025-04-03"},{"cvss_score":8.8,"headline":"Memory corruption in PowerProtect DD","id":"CVE-2024-29176","kev_date_added":null,"published":"2024-06-26"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-02","vendors":["Dell"]},"summary":"A remote low-privileged attacker can exploit an open redirect in Dell PowerProtect DD to cause information disclosure.","url":"https://insights.sbomify.com/CVE-2024-37141/"}