{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-3741 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-3741 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-3741 is a high-severity authentication bypass vulnerability in Electrolink Compact DAB Transmitter, published on 18 Apr 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-3741 and fix it if it is affected.\n\nWhat it is: CVE-2024-3741 is a high-severity authentication bypass vulnerability in Electrolink Compact DAB Transmitter, published on 18 Apr 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-3741 in the wild and no public exploit code.\n\nAffected product: Electrolink Compact DAB Transmitter. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-3741/ (Markdown: https://insights.sbomify.com/CVE-2024-3741/index.md)","id":"CVE-2024-3741","markdown":"https://insights.sbomify.com/CVE-2024-3741/index.md","name":"CVE-2024-3741","record":{"aliases":["GHSA-hhcp-6v36-gh75"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["privilege_escalation","code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Broadcast transmitter","requires_auth":"none","summary":"Attackers can bypass authentication by setting an arbitrary login cookie value to gain full system access to Electrolink transmitters.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-302","name":"Authentication Bypass by Assumed-Immutable Data"}],"description":"Electrolink transmitters are vulnerable to an authentication bypass \nvulnerability affecting the login cookie. An attacker can set an \narbitrary value except 'NO' to the login cookie and have full system \naccess.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Electrolink FM/DAB/TV Transmitter Authentication Bypass by Assumed-Immutable Data","id":"CVE-2024-3741","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Electrolink FM/DAB/TV Transmitter Cleartext Storage of Sensitive Information","id":"CVE-2024-3742"},"packages":[],"prev":{"headline":"cym1102 nginxWebUI reload exec deserialization","id":"CVE-2024-3740"},"products":["Compact DAB Transmitter","Compact FM Transmitter","Digital FM Transmitter","High Power DAB Transmitter","Medium DAB Transmitter","Modular FM Transmitter","UHF TV Transmitter","VHF TV Transmitter"],"published":"2024-04-18","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-01","vendors":["Electrolink"]},"summary":"Attackers can bypass authentication by setting an arbitrary login cookie value to gain full system access to Electrolink transmitters.","url":"https://insights.sbomify.com/CVE-2024-3741/"}