{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-37998 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-37998 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-37998 is a critical authentication bypass vulnerability in Siemens CPCI85 Central Processing/Communication, published on 22 Jul 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-37998 and fix it if it is affected.\n\nWhat it is: CVE-2024-37998 is a critical authentication bypass vulnerability in Siemens CPCI85 Central Processing/Communication, published on 22 Jul 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-37998 in the wild and no public exploit code.\n\nAffected product: Siemens CPCI85 Central Processing/Communication. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-37998/ (Markdown: https://insights.sbomify.com/CVE-2024-37998/index.md)","id":"CVE-2024-37998","markdown":"https://insights.sbomify.com/CVE-2024-37998/index.md","name":"CVE-2024-37998","record":{"aliases":["GHSA-rp56-x26j-363p"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["privilege_escalation","account_takeover"],"network_reachable":"yes","non_default_config":true,"product_category":"Siemens industrial controller","requires_auth":"none","summary":"Attackers can reset admin passwords without current credentials if auto-login is enabled, gaining administrative access to Siemens industrial systems.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":9.3,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-620","name":"Unverified Password Change"}],"description":"A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions \u003c V5.40), SICORE Base system (All versions \u003c V1.4.0). The password of administrative accounts of the affected applications can be reset without requiring the knowledge of the current password, given the auto login is enabled. This could allow an unauthorized attacker to obtain administrative access of the affected applications.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in CPCI85 Central Processing/Communication","id":"CVE-2024-37998","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Privilege escalation in Medicalis Workflow Orchestrator","id":"CVE-2024-37999"},"packages":[],"prev":{"headline":"Memory corruption in JT Open","id":"CVE-2024-37997"},"products":["CPCI85 Central Processing/Communication","SICORE Base system"],"published":"2024-07-22","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-08-02","vendors":["Siemens"]},"summary":"Attackers can reset admin passwords without current credentials if auto-login is enabled, gaining administrative access to Siemens industrial systems.","url":"https://insights.sbomify.com/CVE-2024-37998/"}