{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-38879 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-38879 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-38879 is a high-severity authentication bypass vulnerability in Siemens Omnivise T3000 Application Server R9.2, published on 2 Aug 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-38879 and fix it if it is affected.\n\nWhat it is: CVE-2024-38879 is a high-severity authentication bypass vulnerability in Siemens Omnivise T3000 Application Server R9.2, published on 2 Aug 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-38879 in the wild and no public exploit code.\n\nAffected product: Siemens Omnivise T3000 Application Server R9.2. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-38879/ (Markdown: https://insights.sbomify.com/CVE-2024-38879/index.md)","id":"CVE-2024-38879","markdown":"https://insights.sbomify.com/CVE-2024-38879/index.md","name":"CVE-2024-38879","record":{"aliases":["GHSA-4h47-46m8-cx7g"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["security_bypass","data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SCADA system","requires_auth":"none","summary":"Attackers can bypass authentication and access internal applications by connecting to an exposed port on the public network interface of Siemens Omnivise T3000.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"omnivise_t3000_application_server","vendor":"siemens"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"description":"A vulnerability has been identified in Omnivise T3000 Application Server R9.2 (All versions), Omnivise T3000 R8.2 SP3 (All versions), Omnivise T3000 R8.2 SP4 (All versions). The affected system exposes the port of an internal application on the public network interface allowing an attacker to circumvent authentication and directly access the exposed application.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in Omnivise T3000 Application Server R9.2","id":"CVE-2024-38879","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Weak cryptography in n/a","id":"CVE-2024-38881"},"packages":[],"prev":{"headline":"Path traversal in Omnivise T3000 Application Server R9.2","id":"CVE-2024-38878"},"products":["Omnivise T3000 Application Server R9.2","Omnivise T3000 R8.2 SP3","Omnivise T3000 R8.2 SP4"],"published":"2024-08-02","related":[{"cvss_score":8.5,"headline":"Privilege escalation in Omnivise T3000 Application Server R9.2","id":"CVE-2024-38876","kev_date_added":null,"published":"2024-08-02"},{"cvss_score":8.3,"headline":"Hardcoded credentials in Omnivise T3000 Application Server R9.2","id":"CVE-2024-38877","kev_date_added":null,"published":"2024-08-02"},{"cvss_score":6.9,"headline":"Path traversal in Omnivise T3000 Application Server R9.2","id":"CVE-2024-38878","kev_date_added":null,"published":"2024-08-02"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-11-03","vendors":["Siemens"]},"summary":"Attackers can bypass authentication and access internal applications by connecting to an exposed port on the public network interface of Siemens Omnivise T3000.","url":"https://insights.sbomify.com/CVE-2024-38879/"}