{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-3907 exists.","fix":"No fix has been published for CVE-2024-3907 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-3907 is a high-severity memory corruption vulnerability in Tenda AC500, published on 17 Apr 2024. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-3907 and fix it if it is affected.\n\nWhat it is: CVE-2024-3907 is a high-severity memory corruption vulnerability in Tenda AC500, published on 17 Apr 2024. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-3907 exists.\n\nAffected product: Tenda AC500. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-3907/ (Markdown: https://insights.sbomify.com/CVE-2024-3907/index.md)","id":"CVE-2024-3907","markdown":"https://insights.sbomify.com/CVE-2024-3907/index.md","name":"CVE-2024-3907","record":{"aliases":["GHSA-qxj9-r243-8955"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC500 router","requires_auth":"low_privilege","summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda AC500 router's setcfm form, potentially leading to arbitrary code execution.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"ac500_firmware","vendor":"tenda"}],"cvss":{"score":8.8,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-787","name":"Out-of-bounds Write"},{"id":"CWE-121","name":"Stack-based Buffer Overflow"}],"description":"A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Tenda AC500 setcfm formSetCfm stack-based overflow","id":"CVE-2024-3907","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2024"},"n_packages":0,"n_references":4,"next":{"headline":"Tenda AC500 WriteFacMac formWriteFacMac command injection","id":"CVE-2024-3908"},"packages":[],"prev":{"headline":"Tenda AC500 QuickIndex formQuickIndex stack-based overflow","id":"CVE-2024-3906"},"products":["AC500"],"published":"2024-04-17","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-32318","kev_date_added":null,"published":"2024-04-17"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-25233","kev_date_added":null,"published":"2023-02-27"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-25234","kev_date_added":null,"published":"2023-02-27"},{"cvss_score":8.8,"headline":"Tenda AC500 execCommand R7WebsSecurityHandler stack-based overflow","id":"CVE-2024-3905","kev_date_added":null,"published":"2024-04-17"},{"cvss_score":8.8,"headline":"Tenda AC500 QuickIndex formQuickIndex stack-based overflow","id":"CVE-2024-3906","kev_date_added":null,"published":"2024-04-17"},{"cvss_score":8.8,"headline":"Tenda AC500 execCommand formexeCommand stack-based overflow","id":"CVE-2024-3909","kev_date_added":null,"published":"2024-04-17"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-01","vendors":["Tenda"]},"summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda AC500 router's setcfm form, potentially leading to arbitrary code execution.","url":"https://insights.sbomify.com/CVE-2024-3907/"}