{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-3908 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-3908 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-3908 is a medium-severity command injection vulnerability in Tenda AC500, published on 17 Apr 2024. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-3908 and fix it if it is affected.\n\nWhat it is: CVE-2024-3908 is a medium-severity command injection vulnerability in Tenda AC500, published on 17 Apr 2024. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-3908 in the wild and no public exploit code.\n\nAffected product: Tenda AC500. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-3908/ (Markdown: https://insights.sbomify.com/CVE-2024-3908/index.md)","id":"CVE-2024-3908","markdown":"https://insights.sbomify.com/CVE-2024-3908/index.md","name":"CVE-2024-3908","record":{"aliases":["GHSA-q7j7-mp2g-wrw8"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC500 router","requires_auth":"low_privilege","summary":"Remote attackers can execute arbitrary commands on Tenda AC500 routers via the WriteFacMac interface due to improper input validation.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"ac500_firmware","vendor":"tenda"}],"cvss":{"score":6.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L","version":"3.1"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"description":"A vulnerability classified as critical has been found in Tenda AC500 2.0.1.9(1307). Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261144. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Tenda AC500 WriteFacMac formWriteFacMac command injection","id":"CVE-2024-3908","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2024"},"n_packages":0,"n_references":4,"next":{"headline":"Tenda AC500 execCommand formexeCommand stack-based overflow","id":"CVE-2024-3909"},"packages":[],"prev":{"headline":"Tenda AC500 setcfm formSetCfm stack-based overflow","id":"CVE-2024-3907"},"products":["AC500"],"published":"2024-04-17","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-32318","kev_date_added":null,"published":"2024-04-17"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-25233","kev_date_added":null,"published":"2023-02-27"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-25234","kev_date_added":null,"published":"2023-02-27"},{"cvss_score":8.8,"headline":"Tenda AC500 execCommand R7WebsSecurityHandler stack-based overflow","id":"CVE-2024-3905","kev_date_added":null,"published":"2024-04-17"},{"cvss_score":8.8,"headline":"Tenda AC500 QuickIndex formQuickIndex stack-based overflow","id":"CVE-2024-3906","kev_date_added":null,"published":"2024-04-17"},{"cvss_score":8.8,"headline":"Tenda AC500 setcfm formSetCfm stack-based overflow","id":"CVE-2024-3907","kev_date_added":null,"published":"2024-04-17"},{"cvss_score":8.8,"headline":"Tenda AC500 execCommand formexeCommand stack-based overflow","id":"CVE-2024-3909","kev_date_added":null,"published":"2024-04-17"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-01","vendors":["Tenda"]},"summary":"Remote attackers can execute arbitrary commands on Tenda AC500 routers via the WriteFacMac interface due to improper input validation.","url":"https://insights.sbomify.com/CVE-2024-3908/"}