{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2024-39776 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-39776 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-39776 is a high-severity vulnerability in Avtec Outpost 0810, published on 22 Aug 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-39776 and fix it if it is affected.\n\nWhat it is: CVE-2024-39776 is a high-severity vulnerability in Avtec Outpost 0810, published on 22 Aug 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-39776 in the wild and no public exploit code.\n\nAffected product: Avtec Outpost 0810. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-39776/ (Markdown: https://insights.sbomify.com/CVE-2024-39776/index.md)","id":"CVE-2024-39776","markdown":"https://insights.sbomify.com/CVE-2024-39776/index.md","name":"CVE-2024-39776","record":{"aliases":["GHSA-9347-hgff-8mjv"],"analysis":{"component_type":"server_software","fix_type":"no_fix_stated","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Avtec Outpost","requires_auth":"none","summary":"Attackers can access sensitive data stored in web-accessible directories due to missing access controls in Avtec Outpost.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"outpost_0810_firmware","vendor":"avtecinc"},{"product":"outpost_uploader_utility","vendor":"avtecinc"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-219","name":"Storage of File with Sensitive Data Under Web Root"}],"description":"Avtec Outpost stores sensitive information in an insecure location without proper access controls in place.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Avtec Outpost Storage of File with Sensitive Data Under Web Root","id":"CVE-2024-39776","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Malicious remote can invite itself to an arbitrary local channel","id":"CVE-2024-39777"},"packages":[],"prev":{"headline":"Net Manager has an out-of-bounds read permission bypass vulnerability","id":"CVE-2024-39775"},"products":["Outpost 0810","Outpost Uploader Utility"],"published":"2024-08-22","related":[{"cvss_score":8.7,"headline":"Avtec Outpost Use of Hard-coded Cryptographic Key","id":"CVE-2024-42418","kev_date_added":null,"published":"2024-08-22"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-22","vendors":["Avtec"]},"summary":"Attackers can access sensitive data stored in web-accessible directories due to missing access controls in Avtec Outpost.","url":"https://insights.sbomify.com/CVE-2024-39776/"}