{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-39808 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-39808 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-39808 is a medium-severity denial of service vulnerability in Gallagher Controller 6000 and Controller 7000, published on 11 Sep 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-39808 and fix it if it is affected.\n\nWhat it is: CVE-2024-39808 is a medium-severity denial of service vulnerability in Gallagher Controller 6000 and Controller 7000, published on 11 Sep 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-39808 in the wild and no public exploit code.\n\nAffected product: Gallagher Controller 6000 and Controller 7000. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-39808/ (Markdown: https://insights.sbomify.com/CVE-2024-39808/index.md)","id":"CVE-2024-39808","markdown":"https://insights.sbomify.com/CVE-2024-39808/index.md","name":"CVE-2024-39808","record":{"aliases":["GHSA-9qcw-x77v-9qjh"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Gallagher access controller","requires_auth":"none","summary":"An attacker with physical access to wiring can cause a reboot in Gallagher Controller 6000/7000 devices, resulting in a denial of service.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Gallagher","cpe":[],"cvss":{"score":4.6,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-131","name":"Incorrect Calculation of Buffer Size"}],"description":"Incorrect Calculation of Buffer Size (CWE-131) in the Controller 6000 and Controller 7000 OSDP message handling, allows an attacker with physical access to Controller wiring to instigate a reboot leading to a denial of service. \n\nThis issue affects: Controller 6000 and Controller 7000 9.10 prior to vCR9.10.240816a (distributed in 9.10.1530 (MR2)), 9.00 prior to vCR9.00.240816a (distributed in 9.00.2168 (MR4)), 8.90 prior to vCR8.90.240816a (distributed in 8.90.2155 (MR5)), 8.80 prior to vCR8.80.240816b (distributed in 8.80.1938 (MR6)), all versions of 8.70 and prior.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Denial of service in Controller 6000 and Controller 7000","id":"CVE-2024-39808","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"BIG-IP Next Central Manager vulnerability","id":"CVE-2024-39809"},"packages":[],"prev":{"headline":"Channel IDs of archived/restored channels leaked via webhook events","id":"CVE-2024-39807"},"products":["Controller 6000 and Controller 7000"],"published":"2024-09-11","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-09-11","vendors":["Gallagher"]},"summary":"An attacker with physical access to wiring can cause a reboot in Gallagher Controller 6000/7000 devices, resulting in a denial of service.","url":"https://insights.sbomify.com/CVE-2024-39808/"}