{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-39867 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-39867 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-39867 is a high-severity missing authorization vulnerability in Siemens Sinema Remote Connect Server, published on 9 Jul 2024. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-39867 and fix it if it is affected.\n\nWhat it is: CVE-2024-39867 is a high-severity missing authorization vulnerability in Siemens Sinema Remote Connect Server, published on 9 Jul 2024. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-39867 in the wild and no public exploit code.\n\nAffected product: Siemens Sinema Remote Connect Server. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-39867/ (Markdown: https://insights.sbomify.com/CVE-2024-39867/index.md)","id":"CVE-2024-39867","markdown":"https://insights.sbomify.com/CVE-2024-39867/index.md","name":"CVE-2024-39867","record":{"aliases":["GHSA-p9m2-974m-225h"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SINEMA Remote Connect","requires_auth":"low_privilege","summary":"Unauthenticated attackers can access and edit device configuration information in Siemens SINEMA Remote Connect Server due to missing authorization checks.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"sinema_remote_connect_server","vendor":"siemens"}],"cvss":{"score":7.2,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-425","name":"Direct Request"}],"description":"A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.2 SP1). Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit device configuration information of devices for which they have no privileges.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in SINEMA Remote Connect Server","id":"CVE-2024-39867","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"siemens:sinema_remote_connect_server","products":["siemens:sinema_remote_connect_server"],"type":"missing_authorization","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Missing authorization in SINEMA Remote Connect Server","id":"CVE-2024-39868"},"packages":[],"prev":{"headline":"Privilege escalation in SINEMA Remote Connect Server","id":"CVE-2024-39866"},"products":["SINEMA Remote Connect Server"],"published":"2024-07-09","related":[{"cvss_score":9.8,"headline":"Missing authorization in SINEMA Remote Connect Server","id":"CVE-2022-32257","kev_date_added":null,"published":"2024-03-12"},{"cvss_score":9.8,"headline":"Auth bypass in SINEMA Remote Connect Server","id":"CVE-2019-13918","kev_date_added":null,"published":"2019-09-13"},{"cvss_score":9.3,"headline":"Privilege escalation in SINEMA Remote Connect Server","id":"CVE-2024-39872","kev_date_added":null,"published":"2024-07-09"},{"cvss_score":8.8,"headline":"Missing authorization in SINEMA Remote Connect Server","id":"CVE-2022-32251","kev_date_added":null,"published":"2022-06-14"},{"cvss_score":8.8,"headline":"Command injection in SINEMA Remote Connect Server","id":"CVE-2022-32262","kev_date_added":null,"published":"2022-06-14"},{"cvss_score":8.8,"headline":"Missing authorization in SINEMA Remote Connect Server","id":"CVE-2020-25239","kev_date_added":null,"published":"2021-03-15"},{"cvss_score":8.8,"headline":"Missing authorization in SINEMA Remote Connect Server","id":"CVE-2020-25240","kev_date_added":null,"published":"2021-03-15"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-08-27","vendors":["Siemens"]},"summary":"Unauthenticated attackers can access and edit device configuration information in Siemens SINEMA Remote Connect Server due to missing authorization checks.","url":"https://insights.sbomify.com/CVE-2024-39867/"}