{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-40895 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-40895 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-40895 is a medium-severity command injection vulnerability in FFRI Security, Inc. EDR Plus Pack, published on 30 Jul 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2024-40895 and fix it if it is affected.\n\nWhat it is: CVE-2024-40895 is a medium-severity command injection vulnerability in FFRI Security, Inc. EDR Plus Pack, published on 30 Jul 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2024-40895 in the wild and no public exploit code.\n\nAffected product: FFRI Security, Inc. EDR Plus Pack. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-40895/ (Markdown: https://insights.sbomify.com/CVE-2024-40895/index.md)","id":"CVE-2024-40895","markdown":"https://insights.sbomify.com/CVE-2024-40895/index.md","name":"CVE-2024-40895","record":{"aliases":["GHSA-3cmr-mvgm-pmfq"],"analysis":{"component_type":"desktop_application","fix_type":"patch","impacts":["code_execution"],"network_reachable":"yes","non_default_config":true,"product_category":"FFRI AMC security software","requires_auth":"none","summary":"Remote attackers can execute arbitrary OS commands in FFRI AMC if notification settings use batch files, requiring specific configuration.","user_interaction":"required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"jpcert","cpe":[],"cvss":{"score":6.4,"severity":"medium","source":"cisa-adp","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:L","version":"3.1"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"description":"FFRI AMC versions 3.4.0 to 3.5.3 and some OEM products that implement/bundle FFRI AMC versions 3.4.0 to 3.5.3 allow a remote unauthenticated attacker to execute arbitrary OS commands when certain conditions are met in an environment where the notification program setting is enabled and the executable file path is set to a batch file (.bat) or command file (.cmd) extension.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Command injection in EDR Plus Pack","id":"CVE-2024-40895","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2024"},"n_packages":0,"n_references":4,"next":{"headline":"XML external entity in libxml2","id":"CVE-2024-40896"},"packages":[],"prev":{"headline":"Firewalla BTLE Authenticated Command Injection","id":"CVE-2024-40893"},"products":["EDR Plus Pack","FFRI AMC","FFRI AMC for ActSecure χ"],"published":"2024-07-30","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-08-02","vendors":["FFRI Security, Inc.","NEC Corporation","Sky Co., Ltd."]},"summary":"Remote attackers can execute arbitrary OS commands in FFRI AMC if notification settings use batch files, requiring specific configuration.","url":"https://insights.sbomify.com/CVE-2024-40895/"}