{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-41171 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-41171 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-41171 is a critical vulnerability in Siemens SINUMERIK 828D V4, published on 10 Sep 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-41171 and fix it if it is affected.\n\nWhat it is: CVE-2024-41171 is a critical vulnerability in Siemens SINUMERIK 828D V4, published on 10 Sep 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-41171 in the wild and no public exploit code.\n\nAffected product: Siemens SINUMERIK 828D V4. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-41171/ (Markdown: https://insights.sbomify.com/CVE-2024-41171/index.md)","id":"CVE-2024-41171","markdown":"https://insights.sbomify.com/CVE-2024-41171/index.md","name":"CVE-2024-41171","record":{"aliases":["GHSA-vp7w-7655-3xph"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Siemens CNC controller","requires_auth":"low_privilege","summary":"An authenticated local attacker can escalate privileges on Siemens SINUMERIK CNC controllers due to improper access restrictions on system scripts.","user_interaction":"not_required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":9.3,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","version":"4.0"},"cwes":[{"id":"CWE-732","name":"Incorrect Permission Assignment for Critical Resource"}],"description":"A vulnerability has been identified in SINUMERIK 828D V4 (All versions), SINUMERIK 828D V5 (All versions \u003c V5.24), SINUMERIK 840D sl V4 (All versions), SINUMERIK ONE (All versions \u003c V6.24). Affected devices do not properly enforce access restrictions to scripts that are regularly executed by the system with elevated privileges. This could allow an authenticated local attacker to escalate their privileges in the underlying system.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Privilege escalation in SINUMERIK 828D V4","id":"CVE-2024-41171","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Apache CXF: Unrestricted memory consumption in CXF HTTP clients","id":"CVE-2024-41172"},"packages":[],"prev":{"headline":"Memory corruption in Tecnomatix Plant Simulation V2302","id":"CVE-2024-41170"},"products":["SINUMERIK 828D V4","SINUMERIK 828D V5","SINUMERIK 840D sl V4","SINUMERIK ONE"],"published":"2024-09-10","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-09-10","vendors":["Siemens"]},"summary":"An authenticated local attacker can escalate privileges on Siemens SINUMERIK CNC controllers due to improper access restrictions on system scripts.","url":"https://insights.sbomify.com/CVE-2024-41171/"}