{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-41794 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-41794 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-41794 is a critical vulnerability in Siemens SENTRON 7KT PAC1260 Data Manager, published on 8 Apr 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-41794 and fix it if it is affected.\n\nWhat it is: CVE-2024-41794 is a critical vulnerability in Siemens SENTRON 7KT PAC1260 Data Manager, published on 8 Apr 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-41794 in the wild and no public exploit code.\n\nAffected product: Siemens SENTRON 7KT PAC1260 Data Manager. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-41794/ (Markdown: https://insights.sbomify.com/CVE-2024-41794/index.md)","id":"CVE-2024-41794","markdown":"https://insights.sbomify.com/CVE-2024-41794/index.md","name":"CVE-2024-41794","record":{"aliases":["GHSA-w4wq-mmwq-2c74"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["privilege_escalation","code_execution"],"network_reachable":"yes","non_default_config":true,"product_category":"SENTRON Data Manager","requires_auth":"none","summary":"Hardcoded root credentials allow unauthenticated remote attackers to gain full device access if SSH is enabled.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"7kt_pac1260_data_manager_firmware","vendor":"siemens"}],"cvss":{"score":10,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","version":"4.0"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"}],"description":"A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). Affected devices contain hardcoded credentials for remote access to the device operating system with root privileges. This could allow unauthenticated remote attackers to gain full access to a device, if they are in possession of these credentials and if the ssh service is enabled (e.g., by exploitation of CVE-2024-41793).","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41794","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Cross-site request forgery in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41795"},"packages":[],"prev":{"headline":"Auth bypass in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41793"},"products":["SENTRON 7KT PAC1260 Data Manager"],"published":"2025-04-08","related":[{"cvss_score":9.4,"headline":"Command injection in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41788","kev_date_added":null,"published":"2025-04-08"},{"cvss_score":9.4,"headline":"Command injection in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41789","kev_date_added":null,"published":"2025-04-08"},{"cvss_score":9.4,"headline":"Command injection in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41790","kev_date_added":null,"published":"2025-04-08"},{"cvss_score":9.2,"headline":"Path traversal in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41792","kev_date_added":null,"published":"2025-04-08"},{"cvss_score":7.7,"headline":"Auth bypass in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41793","kev_date_added":null,"published":"2025-04-08"},{"cvss_score":6.9,"headline":"Missing authorization in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41791","kev_date_added":null,"published":"2025-04-08"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-04-08","vendors":["Siemens"]},"summary":"Hardcoded root credentials allow unauthenticated remote attackers to gain full device access if SSH is enabled.","url":"https://insights.sbomify.com/CVE-2024-41794/"}