{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-41795 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-41795 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-41795 is a medium-severity vulnerability in Siemens SENTRON 7KT PAC1260 Data Manager, published on 8 Apr 2025. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2024-41795 and fix it if it is affected.\n\nWhat it is: CVE-2024-41795 is a medium-severity vulnerability in Siemens SENTRON 7KT PAC1260 Data Manager, published on 8 Apr 2025. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2024-41795 in the wild and no public exploit code.\n\nAffected product: Siemens SENTRON 7KT PAC1260 Data Manager. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-41795/ (Markdown: https://insights.sbomify.com/CVE-2024-41795/index.md)","id":"CVE-2024-41795","markdown":"https://insights.sbomify.com/CVE-2024-41795/index.md","name":"CVE-2024-41795","record":{"aliases":["GHSA-w7vx-px98-f5m7"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"SENTRON Data Manager","requires_auth":"none","summary":"An unauthenticated attacker can modify device settings by tricking an administrator into clicking a malicious link.","user_interaction":"required","vuln_class":"csrf"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"7kt_pac1260_data_manager_firmware","vendor":"siemens"}],"cvss":{"score":6.9,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-352","name":"Cross-Site Request Forgery"}],"description":"A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices is vulnerable to Cross-Site Request Forgery (CSRF) attacks. This could allow an unauthenticated attacker to change arbitrary device settings by tricking a legitimate device administrator to click on a malicious link.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site request forgery in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41795","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"csrf","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Auth bypass in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41796"},"packages":[],"prev":{"headline":"Hardcoded credentials in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41794"},"products":["SENTRON 7KT PAC1260 Data Manager"],"published":"2025-04-08","related":[{"cvss_score":10,"headline":"Hardcoded credentials in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41794","kev_date_added":null,"published":"2025-04-08"},{"cvss_score":9.4,"headline":"Command injection in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41788","kev_date_added":null,"published":"2025-04-08"},{"cvss_score":9.4,"headline":"Command injection in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41789","kev_date_added":null,"published":"2025-04-08"},{"cvss_score":9.4,"headline":"Command injection in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41790","kev_date_added":null,"published":"2025-04-08"},{"cvss_score":9.2,"headline":"Path traversal in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41792","kev_date_added":null,"published":"2025-04-08"},{"cvss_score":7.7,"headline":"Auth bypass in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41793","kev_date_added":null,"published":"2025-04-08"},{"cvss_score":6.9,"headline":"Missing authorization in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41791","kev_date_added":null,"published":"2025-04-08"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-04-08","vendors":["Siemens"]},"summary":"An unauthenticated attacker can modify device settings by tricking an administrator into clicking a malicious link.","url":"https://insights.sbomify.com/CVE-2024-41795/"}