{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-41796 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-41796 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-41796 is a medium-severity authentication bypass vulnerability in Siemens SENTRON 7KT PAC1260 Data Manager, published on 8 Apr 2025. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2024-41796 and fix it if it is affected.\n\nWhat it is: CVE-2024-41796 is a medium-severity authentication bypass vulnerability in Siemens SENTRON 7KT PAC1260 Data Manager, published on 8 Apr 2025. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2024-41796 in the wild and no public exploit code.\n\nAffected product: Siemens SENTRON 7KT PAC1260 Data Manager. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-41796/ (Markdown: https://insights.sbomify.com/CVE-2024-41796/index.md)","id":"CVE-2024-41796","markdown":"https://insights.sbomify.com/CVE-2024-41796/index.md","name":"CVE-2024-41796","record":{"aliases":["GHSA-j3pg-9jg5-pj7f"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"SENTRON Data Manager","requires_auth":"none","summary":"An unauthenticated attacker can change the login password via CSRF, leading to account takeover on Siemens SENTRON Data Manager devices.","user_interaction":"required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"7kt_pac1260_data_manager_firmware","vendor":"siemens"}],"cvss":{"score":6.9,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-620","name":"Unverified Password Change"}],"description":"A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices allows to change the login password without knowing the current password. In combination with a prepared CSRF attack (CVE-2024-41795) an unauthenticated attacker could be able to set the password to an attacker-controlled value.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41796","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Privilege escalation in RUGGEDCOM RST2428P","id":"CVE-2024-41797"},"packages":[],"prev":{"headline":"Cross-site request forgery in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41795"},"products":["SENTRON 7KT PAC1260 Data Manager"],"published":"2025-04-08","related":[{"cvss_score":10,"headline":"Hardcoded credentials in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41794","kev_date_added":null,"published":"2025-04-08"},{"cvss_score":9.4,"headline":"Command injection in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41788","kev_date_added":null,"published":"2025-04-08"},{"cvss_score":9.4,"headline":"Command injection in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41789","kev_date_added":null,"published":"2025-04-08"},{"cvss_score":9.4,"headline":"Command injection in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41790","kev_date_added":null,"published":"2025-04-08"},{"cvss_score":9.2,"headline":"Path traversal in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41792","kev_date_added":null,"published":"2025-04-08"},{"cvss_score":7.7,"headline":"Auth bypass in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41793","kev_date_added":null,"published":"2025-04-08"},{"cvss_score":6.9,"headline":"Missing authorization in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41791","kev_date_added":null,"published":"2025-04-08"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-04-08","vendors":["Siemens"]},"summary":"An unauthenticated attacker can change the login password via CSRF, leading to account takeover on Siemens SENTRON Data Manager devices.","url":"https://insights.sbomify.com/CVE-2024-41796/"}