{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-41797 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-41797 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-41797 is a medium-severity vulnerability in Siemens RUGGEDCOM RST2428P, published on 10 Jun 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-41797 and fix it if it is affected.\n\nWhat it is: CVE-2024-41797 is a medium-severity vulnerability in Siemens RUGGEDCOM RST2428P, published on 10 Jun 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-41797 in the wild and no public exploit code.\n\nAffected product: Siemens RUGGEDCOM RST2428P. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-41797/ (Markdown: https://insights.sbomify.com/CVE-2024-41797/index.md)","id":"CVE-2024-41797","markdown":"https://insights.sbomify.com/CVE-2024-41797/index.md","name":"CVE-2024-41797","record":{"aliases":["GHSA-4fhp-55v2-x26m"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SCALANCE switch","requires_auth":"low_privilege","summary":"Attackers can escalate privileges on Siemens SCALANCE and RUGGEDCOM network switches, potentially gaining unauthorized administrative control.","user_interaction":"not_required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-269","name":"Improper Privilege Management"}],"description":"A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions \u003c V3.1), SCALANCE XC316-8 (6GK5324-8TS00-2AC2) (All versions \u003c V3.1), SCALANCE XC324-4 (6GK5328-4TS00-2AC2) (All versions \u003c V3.1), SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2) (All versions \u003c V3.1), SCALANCE XC332 (6GK5332-0GA00-2AC2) (All versions \u003c V3.1), SCALANCE XC416-8 (6GK5424-8TR00-2AC2) (All versions \u003c V3.1), SCALANCE XC424-4 (6GK5428-4TR00-2AC2) (All versions \u003c V3.1), SCALANCE XC432 (6GK5432-0GR00-2AC2) (All versions \u003c V3.1), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions \u003c V3.1), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions \u003c V3.1), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions \u003c V3.1), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions \u003c V3.1), SCALANCE XR302-32 (6GK5334-5TS00-2AR3) (All versions \u003c V3.1), SCALANCE XR302-32 (6GK5334-5TS00-3AR3) (All versions \u003c V3.1), SCALANCE XR302-32 (6GK5334-5TS00-4AR3) (All versions \u003c V3.1), SCALANCE XR322-12 (6GK5334-3TS00-2AR3) (All versions \u003c V3.1), SCALANCE XR322-12 (6GK5334-3TS00-3AR3) (All versions \u003c V3.1), SCALANCE XR322-12 (6GK5334-3TS00-4AR3) (All versions \u003c V3.1), SCALANCE XR326-8 (6GK5334-2TS00-2AR3) (All versions \u003c V3.1), SCALANCE XR326-8 (6GK5334-2TS00-3AR3) (All versions \u003c V3.1), SCALANCE XR326-8 (6GK5334-2TS00-4AR3) (All versions \u003c V3.1), SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3) (All versions \u003c V3.1), SCALANCE XR502-32 (6GK5534-5TR00-2AR3) (All versions \u003c V3.1), SCALANCE XR502-32 (6GK5534-5TR00-3AR3) (All versions \u003c V3.1), SCALANCE XR502-32 (6GK5534-5TR00-4AR3) (All versions \u003c V3.1), SCALANCE XR522-12 (6GK5534-3TR00-2AR3) (All versions \u003c V3.1), SCALANCE XR522-12 (6GK5534-3TR00-3AR3) (All versions \u003c V3.1), SCALANCE XR522-12 (6GK5534-3TR00-4AR3) (All versions \u003c V3.1), SCALANCE XR526-8 (6GK5534-2TR00-2AR3) (All versions \u003c V3.1), SCALANCE XR526-8 (6GK5534-2TR00-3AR3) (All versions \u003c V3.1), SCALANCE XR526-8 (6GK5534-2TR00-4AR3) (All versions \u003c V3.1), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions \u003c V3.1), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions \u003c V3.1), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions \u003c V3.1), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions \u003c V3.1), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions \u003c V3.1), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions \u003c V3.1), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions \u003c V3.1), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions \u003c V3.1), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions \u003c V3.1), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions \u003c V3.1). Affected devices contain an incorrect authorization check vulnerability. This could allow an authenticated remote attacker with \"guest\" role to invoke an internal \"do system\" command which exceeds their privileges. This command allows the execution of certain low-risk actions, the most critical of which is clearing the local system log.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Privilege escalation in RUGGEDCOM RST2428P","id":"CVE-2024-41797","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Auth bypass in SENTRON 7KM PAC3200","id":"CVE-2024-41798"},"packages":[],"prev":{"headline":"Auth bypass in SENTRON 7KT PAC1260 Data Manager","id":"CVE-2024-41796"},"products":["RUGGEDCOM RST2428P","SCALANCE XC316-8","SCALANCE XC324-4","SCALANCE XC324-4 EEC","SCALANCE XC332","SCALANCE XC416-8","SCALANCE XC424-4","SCALANCE XC432","SCALANCE XCH328","SCALANCE XCM324","SCALANCE XCM328","SCALANCE XCM332","SCALANCE XR302-32","SCALANCE XR322-12","SCALANCE XR326-8","SCALANCE XR326-8 EEC","SCALANCE XR502-32","SCALANCE XR522-12","SCALANCE XR526-8","SCALANCE XRH334 (24 V DC, 8xFO, CC)","SCALANCE XRM334 (230 V AC, 12xFO)","SCALANCE XRM334 (230 V AC, 8xFO)","SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)","SCALANCE XRM334 (24 V DC, 12xFO)","SCALANCE XRM334 (24 V DC, 8xFO)","SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)","SCALANCE XRM334 (2x230 V AC, 12xFO)","SCALANCE XRM334 (2x230 V AC, 8xFO)","SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)"],"published":"2025-06-10","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-06-10","vendors":["Siemens"]},"summary":"Attackers can escalate privileges on Siemens SCALANCE and RUGGEDCOM network switches, potentially gaining unauthorized administrative control.","url":"https://insights.sbomify.com/CVE-2024-41797/"}