{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-41905 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-41905 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-41905 is a high-severity missing authorization vulnerability in Siemens SINEC Traffic Analyzer, published on 13 Aug 2024. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-41905 and fix it if it is affected.\n\nWhat it is: CVE-2024-41905 is a high-severity missing authorization vulnerability in Siemens SINEC Traffic Analyzer, published on 13 Aug 2024. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-41905 in the wild and no public exploit code.\n\nAffected product: Siemens SINEC Traffic Analyzer. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-41905/ (Markdown: https://insights.sbomify.com/CVE-2024-41905/index.md)","id":"CVE-2024-41905","markdown":"https://insights.sbomify.com/CVE-2024-41905/index.md","name":"CVE-2024-41905","record":{"aliases":["GHSA-7jf9-xqjc-725f"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"SINEC Traffic Analyzer","requires_auth":"low_privilege","summary":"An authenticated low-privilege attacker can access sensitive files due to missing access controls in Siemens SINEC Traffic Analyzer.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"sinec_traffic_analyzer","vendor":"siemens"}],"cvss":{"score":7.6,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-284","name":"Improper Access Control"}],"description":"A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions \u003c V2.0). The affected application do not have access control for accessing the files. This could allow an authenticated attacker with low privilege's to get access to sensitive information.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in SINEC Traffic Analyzer","id":"CVE-2024-41905","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in SINEC Traffic Analyzer","id":"CVE-2024-41906"},"packages":[],"prev":{"headline":"Auth bypass in SINEC Traffic Analyzer","id":"CVE-2024-41904"},"products":["SINEC Traffic Analyzer"],"published":"2024-08-13","related":[{"cvss_score":8.8,"headline":"Privilege escalation in SINEC Traffic Analyzer","id":"CVE-2025-40767","kev_date_added":null,"published":"2025-08-12"},{"cvss_score":8.7,"headline":"Auth bypass in SINEC Traffic Analyzer","id":"CVE-2024-41904","kev_date_added":null,"published":"2024-08-13"},{"cvss_score":8.5,"headline":"Auth bypass in SINEC Traffic Analyzer","id":"CVE-2024-35206","kev_date_added":null,"published":"2024-06-11"},{"cvss_score":8.5,"headline":"Cross-site request forgery in SINEC Traffic Analyzer","id":"CVE-2024-35207","kev_date_added":null,"published":"2024-06-11"},{"cvss_score":7.5,"headline":"Other in SINEC Traffic Analyzer","id":"CVE-2025-40770","kev_date_added":null,"published":"2025-08-12"},{"cvss_score":7.5,"headline":"Privilege escalation in SINEC Traffic Analyzer","id":"CVE-2024-41903","kev_date_added":null,"published":"2024-08-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-08-13","vendors":["Siemens"]},"summary":"An authenticated low-privilege attacker can access sensitive files due to missing access controls in Siemens SINEC Traffic Analyzer.","url":"https://insights.sbomify.com/CVE-2024-41905/"}