{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-41907 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-41907 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-41907 is a low-severity vulnerability in Siemens SINEC Traffic Analyzer, published on 13 Aug 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2024-41907 and fix it if it is affected.\n\nWhat it is: CVE-2024-41907 is a low-severity vulnerability in Siemens SINEC Traffic Analyzer, published on 13 Aug 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2024-41907 in the wild and no public exploit code.\n\nAffected product: Siemens SINEC Traffic Analyzer. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-41907/ (Markdown: https://insights.sbomify.com/CVE-2024-41907/index.md)","id":"CVE-2024-41907","markdown":"https://insights.sbomify.com/CVE-2024-41907/index.md","name":"CVE-2024-41907","record":{"aliases":["GHSA-jm3q-4p3v-cv8w"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SINEC Traffic Analyzer","requires_auth":"none","summary":"Missing HTTP security headers in SINEC Traffic Analyzer allow attackers to facilitate clickjacking attacks against the web interface.","user_interaction":"required","vuln_class":"security_feature_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"sinec_traffic_analyzer","vendor":"siemens"}],"cvss":{"score":2.1,"severity":"low","source":"cna","vector":"CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:A/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-358","name":"Improperly Implemented Security Check for Standard"}],"description":"A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions \u003c V2.0). The affected application is missing general HTTP security headers in the web server. This could allow an attacker to make the servers more prone to clickjacking attack.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Security feature bypass in SINEC Traffic Analyzer","id":"CVE-2024-41907","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"security_feature_bypass","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Memory corruption in NX","id":"CVE-2024-41908"},"packages":[],"prev":{"headline":"Information disclosure in SINEC Traffic Analyzer","id":"CVE-2024-41906"},"products":["SINEC Traffic Analyzer"],"published":"2024-08-13","related":[{"cvss_score":8.8,"headline":"Privilege escalation in SINEC Traffic Analyzer","id":"CVE-2025-40767","kev_date_added":null,"published":"2025-08-12"},{"cvss_score":8.7,"headline":"Auth bypass in SINEC Traffic Analyzer","id":"CVE-2024-41904","kev_date_added":null,"published":"2024-08-13"},{"cvss_score":8.5,"headline":"Auth bypass in SINEC Traffic Analyzer","id":"CVE-2024-35206","kev_date_added":null,"published":"2024-06-11"},{"cvss_score":8.5,"headline":"Cross-site request forgery in SINEC Traffic Analyzer","id":"CVE-2024-35207","kev_date_added":null,"published":"2024-06-11"},{"cvss_score":7.6,"headline":"Missing authorization in SINEC Traffic Analyzer","id":"CVE-2024-41905","kev_date_added":null,"published":"2024-08-13"},{"cvss_score":7.5,"headline":"Other in SINEC Traffic Analyzer","id":"CVE-2025-40770","kev_date_added":null,"published":"2025-08-12"},{"cvss_score":7.5,"headline":"Privilege escalation in SINEC Traffic Analyzer","id":"CVE-2024-41903","kev_date_added":null,"published":"2024-08-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-13","vendors":["Siemens"]},"summary":"Missing HTTP security headers in SINEC Traffic Analyzer allow attackers to facilitate clickjacking attacks against the web interface.","url":"https://insights.sbomify.com/CVE-2024-41907/"}