CVE-2024-41978 Information disclosure in RUGGEDCOM RM1224 LTE(4G) EU
An authenticated attacker can read sensitive 2FA token generation data from log files to forge tokens and take over other user accounts.
- Exploited in the wild
- Not known
- Login needed
- Any signed-in user
- Attackable
- Over the internet
- Victim action needed
- Not needed
- Fix
- None listed
What is CVE-2024-41978?
CVE-2024-41978 is a high-severity vulnerability in Siemens RUGGEDCOM RM1224 LTE(4G) EU, published on 13 Aug 2024. Any signed-in user can exploit it over the network, with no action from the victim.
Official description
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.1), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.1), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.1), SCALANCE M812-1 ADSL-Router family (All versions < V8.1), SCALANCE M816-1 ADSL-Router family (All versions < V8.1), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.1), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.1), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.1), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.1), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.1), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.1), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.1), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.1), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.1), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.1), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.1), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.1), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.1), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.1), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.1), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.1). Affected devices insert sensitive information about the generation of 2FA tokens into log files. This could allow an authenticated remote attacker to forge 2FA tokens of other users.
Weakness: CWE-532
Which versions are affected by CVE-2024-41978?
It affects 26 products.
Products include Siemens Ruggedcom Rm1224 Lte\(4g\) Eu Firmware, Siemens Ruggedcom Rm1224 Lte\(4g\) Nam Firmware, Siemens Scalance M804pb Firmware, Siemens Scalance M812-1 \(Annex A\) Firmware, Siemens Scalance M812-1 \(Annex B\) Firmware, Siemens Scalance M816-1 \(Annex A\) Firmware and 20 more.
How do I fix CVE-2024-41978?
No fix has been published for CVE-2024-41978 yet. Limit exposure of the affected software until one is available.
Is CVE-2024-41978 being exploited?
There is no known exploitation of CVE-2024-41978 in the wild and no public exploit code.
Other vulnerabilities in Siemens RUGGEDCOM RM1224 LTE(4G) EU
- CVE-2024-50557 Command injection in RUGGEDCOM RM1224 LTE(4G) EU
- CVE-2024-50572 Command injection in RUGGEDCOM RM1224 LTE(4G) EU
- CVE-2024-41976 Code injection in RUGGEDCOM RM1224 LTE(4G) EU
- CVE-2024-41977 Privilege escalation in RUGGEDCOM RM1224 LTE(4G) EU
- CVE-2022-46140 Weak cryptography in RUGGEDCOM RM1224 LTE(4G) EU
Sources