CVE-2024-43662 Authenticated arbitrary file upload to /tmp/ and /tmp/upload/

Medium 5.3 Published Updated

Authenticated attackers can upload arbitrary files to temporary directories on Iocharger EV chargers, potentially modifying device integrity.

Exploited in the wild
Not known
Login needed
Any signed-in user
Attackable
Over the internet
Victim action needed
Not needed
Fix
None listed

What is CVE-2024-43662?

CVE-2024-43662 is a medium-severity vulnerability in Iocharger firmware for AC models, published on 9 Jan 2025. Any signed-in user can exploit it over the network, with no action from the victim.

Official description

The <redacted>.exe or <redacted>.exe CGI binary can be used to upload arbitrary files to /tmp/upload/ or /tmp/ respectively as any user, although the user interface for uploading files is only shown to the iocadmin user.

This issue affects Iocharger firmware for AC models before version 24120701.

Likelihood: Moderate – An attacker will need to have knowledge of this CGI binary, e.g. by finding it in firmware. Furthermore, the attacker will need a (low privilege) account to gain access to the <redacted>.exe or <redacted>.exe CGI binary and upload the file, or convince a user with such access to upload it.

Impact: Low – The attacker can upload arbitrary files to /tmp/upload/ or /tmp/. However, the attacker is unable to access or use these files without other vulnerabilities.

CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). Artitrary files can be uploaded, be these files will not be in a location where they can influence confidentiality or availability and have a minimal impact on device integrity (VC:N/VI:L/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect this vulnerability to have a safety impact. The attack can be automated (AU:Y).

Weakness: CWE-862, CWE-434

Which versions are affected by CVE-2024-43662?

How do I fix CVE-2024-43662?

No fix has been published for CVE-2024-43662 yet. Limit exposure of the affected software until one is available.

Is CVE-2024-43662 being exploited?

There is no known exploitation of CVE-2024-43662 in the wild and no public exploit code.

Sources

Also known as GHSA-2q25-7xw9-h7cj.

Is CVE-2024-43662 in your software?

Upload an SBOM and sbomify checks it against every vulnerability here, every day.

Check your SBOMs for free