{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-45250 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-45250 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-45250 is a medium-severity vulnerability in ZKteco iClock v3.1-168, published on 6 Oct 2024. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-45250 and fix it if it is affected.\n\nWhat it is: CVE-2024-45250 is a medium-severity vulnerability in ZKteco iClock v3.1-168, published on 6 Oct 2024. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-45250 in the wild and no public exploit code.\n\nAffected product: ZKteco iClock v3.1-168. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-45250/ (Markdown: https://insights.sbomify.com/CVE-2024-45250/index.md)","id":"CVE-2024-45250","markdown":"https://insights.sbomify.com/CVE-2024-45250/index.md","name":"CVE-2024-45250","record":{"aliases":["GHSA-gj25-c4vg-x77w"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"ZKteco iClock","requires_auth":"low_privilege","summary":"An attacker can access sensitive information from the ZKteco iClock device without authorization.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"INCD","cpe":[],"cvss":{"score":4.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"ZKteco – CWE 200 Exposure of Sensitive Information to an Unauthorized Actor","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"ZKteco – CWE 200 Exposure of Sensitive Information to an Unauthorized Actor","id":"CVE-2024-45250","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Elsight – CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","id":"CVE-2024-45251"},"packages":[],"prev":{"headline":"Cavok – CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')","id":"CVE-2024-45249"},"products":["iClock v3.1-168"],"published":"2024-10-06","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-10-07","vendors":["ZKteco"]},"summary":"An attacker can access sensitive information from the ZKteco iClock device without authorization.","url":"https://insights.sbomify.com/CVE-2024-45250/"}