{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-45884 exists.","fix":"No fix has been published for CVE-2024-45884 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-45884 is a high-severity command injection vulnerability in n/a, published on 4 Nov 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-45884 and fix it if it is affected.\n\nWhat it is: CVE-2024-45884 is a high-severity command injection vulnerability in n/a, published on 4 Nov 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-45884 exists.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-45884/ (Markdown: https://insights.sbomify.com/CVE-2024-45884/index.md)","id":"CVE-2024-45884","markdown":"https://insights.sbomify.com/CVE-2024-45884/index.md","name":"CVE-2024-45884","record":{"aliases":["GHSA-qcw6-77mc-69mj"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"DrayTek router","requires_auth":"low_privilege","summary":"An authenticated attacker can execute arbitrary commands on DrayTek Vigor3900 routers via the setSWMGroup action parameter.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"vigor3900_firmware","vendor":"draytek"}],"cvss":{"score":8,"severity":"high","source":"cisa-adp","vector":"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"description":"DrayTek Vigor3900 1.5.1.3 contains a post-authentication command injection vulnerability. This vulnerability occurs when the `action` parameter in `cgi-bin/mainfunction.cgi` is set to `setSWMGroup.`","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Command injection in n/a","id":"CVE-2024-45884","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2024"},"n_packages":0,"n_references":2,"next":{"headline":"Command injection in n/a","id":"CVE-2024-45885"},"packages":[],"prev":{"headline":"Command injection in n/a","id":"CVE-2024-45882"},"products":["n/a"],"published":"2024-11-04","related":[{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2024-51255","kev_date_added":null,"published":"2024-10-31"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2024-51259","kev_date_added":null,"published":"2024-10-31"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2024-51260","kev_date_added":null,"published":"2024-10-31"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2024-51298","kev_date_added":null,"published":"2024-10-30"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2024-48153","kev_date_added":null,"published":"2024-10-14"},{"cvss_score":8.8,"headline":"Command injection in n/a","id":"CVE-2024-51254","kev_date_added":null,"published":"2024-10-31"},{"cvss_score":8.8,"headline":"Command injection in n/a","id":"CVE-2024-51257","kev_date_added":null,"published":"2024-10-30"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-11-04","vendors":["n/a"]},"summary":"An authenticated attacker can execute arbitrary commands on DrayTek Vigor3900 routers via the setSWMGroup action parameter.","url":"https://insights.sbomify.com/CVE-2024-45884/"}