{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-4708 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-4708 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-4708 is a critical vulnerability in mySCADA myPRO, published on 2 Jul 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-4708 and fix it if it is affected.\n\nWhat it is: CVE-2024-4708 is a critical vulnerability in mySCADA myPRO, published on 2 Jul 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-4708 in the wild and no public exploit code.\n\nAffected product: mySCADA myPRO. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-4708/ (Markdown: https://insights.sbomify.com/CVE-2024-4708/index.md)","id":"CVE-2024-4708","markdown":"https://insights.sbomify.com/CVE-2024-4708/index.md","name":"CVE-2024-4708","record":{"aliases":["GHSA-8w3c-2jv9-vpm4"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"mySCADA myPRO","requires_auth":"none","summary":"Attackers can use hard-coded credentials to remotely execute code on mySCADA myPRO devices, posing a critical risk to industrial control systems.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"mypro","vendor":"myscada"}],"cvss":{"score":9.3,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"},{"id":"CWE-259","name":"Use of Hard-coded Password"}],"description":"mySCADA myPRO \n\nuses a hard-coded password which could allow an attacker to remotely execute code on the affected device.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"mySCADA myPRO Use of Hard-coded Password","id":"CVE-2024-4708","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2024"},"n_packages":0,"n_references":2,"next":{"headline":"Cross-site scripting in Fluent Forms – Customizable Contact Forms, Survey, Quiz, \u0026 Conversational Form Builder","id":"CVE-2024-4709"},"packages":[],"prev":{"headline":"Cross-site scripting in Materialis Companion","id":"CVE-2024-4707"},"products":["myPRO"],"published":"2024-07-02","related":[{"cvss_score":10,"headline":"mySCADA myPRO Manager Missing Authentication for Critical Function","id":"CVE-2025-24865","kev_date_added":null,"published":"2025-02-13"},{"cvss_score":10,"headline":"mySCADA myPRO","id":"CVE-2021-22657","kev_date_added":null,"published":"2021-12-23"},{"cvss_score":10,"headline":"mySCADA myPRO","id":"CVE-2021-23198","kev_date_added":null,"published":"2021-12-23"},{"cvss_score":10,"headline":"mySCADA myPRO","id":"CVE-2021-43981","kev_date_added":null,"published":"2021-12-23"},{"cvss_score":10,"headline":"mySCADA myPRO","id":"CVE-2021-43984","kev_date_added":null,"published":"2021-12-23"},{"cvss_score":10,"headline":"mySCADA myPRO","id":"CVE-2021-44453","kev_date_added":null,"published":"2021-12-23"},{"cvss_score":9.9,"headline":"mySCADA myPRO Command Injection","id":"CVE-2022-2234","kev_date_added":null,"published":"2022-08-24"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-08-01","vendors":["mySCADA"]},"summary":"Attackers can use hard-coded credentials to remotely execute code on mySCADA myPRO devices, posing a critical risk to industrial control systems.","url":"https://insights.sbomify.com/CVE-2024-4708/"}