{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-47258 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-47258 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-47258 is a high-severity vulnerability in 2N Access Commander, published on 6 Feb 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-47258 and fix it if it is affected.\n\nWhat it is: CVE-2024-47258 is a high-severity vulnerability in 2N Access Commander, published on 6 Feb 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-47258 in the wild and no public exploit code.\n\nAffected product: 2N Access Commander. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-47258/ (Markdown: https://insights.sbomify.com/CVE-2024-47258/index.md)","id":"CVE-2024-47258","markdown":"https://insights.sbomify.com/CVE-2024-47258/index.md","name":"CVE-2024-47258","record":{"aliases":["GHSA-gcp8-45qv-x5w6"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["data_read","security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Access control software","requires_auth":"none","summary":"Attackers can intercept traffic between 2N Access Commander and edge devices due to missing certificate validation, exposing sensitive data.","user_interaction":"not_required","vuln_class":"security_feature_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Axis","cpe":[],"cvss":{"score":8.1,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","version":"3.1"},"cwes":[{"id":"CWE-295","name":"Improper Certificate Validation"}],"description":"2N Access Commander version 2.1 and prior is vulnerable in default settings to Man In The Middle attack due to not verifying certificates of 2N edge devices. \n\n2N has currently released an updated version 3.3 of 2N Access Commander, with added Certificate Fingerprint Verification. Since version 2.2 of 2N Access Commander (released in February 2022) it is also possible to enforce TLS certificate validation.It is recommended that all customers update 2N Access Commander to the latest version and use one of two mentioned practices.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Security feature bypass in 2N Access Commander","id":"CVE-2024-47258","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"security_feature_bypass","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Command injection in AXIS OS","id":"CVE-2024-47259"},"packages":[],"prev":{"headline":"Denial of service in AXIS P1428-E Network Camera","id":"CVE-2024-47257"},"products":["2N Access Commander"],"published":"2025-02-06","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-01-09","vendors":["2N"]},"summary":"Attackers can intercept traffic between 2N Access Commander and edge devices due to missing certificate validation, exposing sensitive data.","url":"https://insights.sbomify.com/CVE-2024-47258/"}