{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-47562 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-47562 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-47562 is a critical command injection vulnerability in Siemens SINEC Security Monitor, published on 8 Oct 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-47562 and fix it if it is affected.\n\nWhat it is: CVE-2024-47562 is a critical command injection vulnerability in Siemens SINEC Security Monitor, published on 8 Oct 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-47562 in the wild and no public exploit code.\n\nAffected product: Siemens SINEC Security Monitor. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-47562/ (Markdown: https://insights.sbomify.com/CVE-2024-47562/index.md)","id":"CVE-2024-47562","markdown":"https://insights.sbomify.com/CVE-2024-47562/index.md","name":"CVE-2024-47562","record":{"aliases":["GHSA-hq54-fc5j-p5hh"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["code_execution","privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"SINEC Security Monitor","requires_auth":"low_privilege","summary":"An authenticated local attacker can execute privileged OS commands via improper input neutralization in the ssmctl-client command.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"sinec_security_monitor","vendor":"siemens"}],"cvss":{"score":9.3,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","version":"4.0"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"description":"A vulnerability has been identified in SINEC Security Monitor (All versions \u003c V4.9.0). The affected application does not properly neutralize special elements in user input to the ```ssmctl-client``` command.\r\nThis could allow an authenticated, lowly privileged local attacker to execute privileged commands in the underlying OS.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Command injection in SINEC Security Monitor","id":"CVE-2024-47562","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in SINEC Security Monitor","id":"CVE-2024-47563"},"packages":[],"prev":{"headline":"Apache Avro Java SDK: Arbitrary Code Execution when reading Avro schema (Java SDK)","id":"CVE-2024-47561"},"products":["SINEC Security Monitor"],"published":"2024-10-08","related":[{"cvss_score":9.4,"headline":"Command injection in SINEC Security Monitor","id":"CVE-2024-47553","kev_date_added":null,"published":"2024-10-08"},{"cvss_score":8.4,"headline":"Missing authorization in SINEC Security Monitor","id":"CVE-2025-40830","kev_date_added":null,"published":"2025-12-09"},{"cvss_score":7.1,"headline":"Denial of service in SINEC Security Monitor","id":"CVE-2025-40831","kev_date_added":null,"published":"2025-12-09"},{"cvss_score":6.9,"headline":"Path traversal in SINEC Security Monitor","id":"CVE-2024-47563","kev_date_added":null,"published":"2024-10-08"},{"cvss_score":5.3,"headline":"Information disclosure in SINEC Security Monitor","id":"CVE-2026-27661","kev_date_added":null,"published":"2026-03-10"},{"cvss_score":5.3,"headline":"Business logic in SINEC Security Monitor","id":"CVE-2024-47565","kev_date_added":null,"published":"2024-10-08"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-03-10","vendors":["Siemens"]},"summary":"An authenticated local attacker can execute privileged OS commands via improper input neutralization in the ssmctl-client command.","url":"https://insights.sbomify.com/CVE-2024-47562/"}