CVE-2024-47901 Command injection in InterMesh 7177 Hybrid 2.0 Subscriber
Unauthenticated remote attackers can execute arbitrary code with root privileges on Siemens InterMesh subscribers via unsanitized GET requests.
- Exploited in the wild
- Not known
- Login needed
- Not needed
- Attackable
- Over the internet
- Victim action needed
- Not needed
- Fix
- None listed
What is CVE-2024-47901?
CVE-2024-47901 is a critical command injection vulnerability in Siemens InterMesh 7177 Hybrid 2.0 Subscriber, published on 23 Oct 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.
Official description
A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not sanitize the input parameters in specific GET requests that allow for code execution on operating system level. In combination with other vulnerabilities (CVE-2024-47902, CVE-2024-47903, CVE-2024-47904) this could allow an unauthenticated remote attacker to execute arbitrary code with root privileges.
Weakness: CWE-78
Which versions are affected by CVE-2024-47901?
It affects 2 products.
Products include Siemens Intermesh 7177 Hybrid 2.0 Subscriber, Siemens Intermesh 7707 Fire Subscriber Firmware.
How do I fix CVE-2024-47901?
No fix has been published for CVE-2024-47901 yet. Limit exposure of the affected software until one is available.
Upgrade, and pass arguments to programs as a list instead of through a shell. More about Command injection.
Is CVE-2024-47901 being exploited?
There is no known exploitation of CVE-2024-47901 in the wild and no public exploit code.
Other vulnerabilities in Siemens InterMesh 7177 Hybrid 2.0 Subscriber
Sources
Also known as GHSA-9pjf-m6v9-3r5j.