{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2024-47904 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-47904 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-47904 is a high-severity vulnerability in Siemens InterMesh 7177 Hybrid 2.0 Subscriber, published on 23 Oct 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-47904 and fix it if it is affected.\n\nWhat it is: CVE-2024-47904 is a high-severity vulnerability in Siemens InterMesh 7177 Hybrid 2.0 Subscriber, published on 23 Oct 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-47904 in the wild and no public exploit code.\n\nAffected product: Siemens InterMesh 7177 Hybrid 2.0 Subscriber. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-47904/ (Markdown: https://insights.sbomify.com/CVE-2024-47904/index.md)","id":"CVE-2024-47904","markdown":"https://insights.sbomify.com/CVE-2024-47904/index.md","name":"CVE-2024-47904","record":{"aliases":["GHSA-96m4-wxp2-5cfp"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["privilege_escalation","code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Siemens InterMesh subscriber","requires_auth":"low_privilege","summary":"An authenticated local attacker can exploit a SUID binary to execute arbitrary commands with root privileges on Siemens InterMesh subscriber devices.","user_interaction":"not_required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"intermesh_7177_hybrid_2.0_subscriber","vendor":"siemens"},{"product":"intermesh_7707_fire_subscriber_firmware","vendor":"siemens"}],"cvss":{"score":8.5,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-266","name":"Incorrect Privilege Assignment"}],"description":"A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions \u003c V8.2.12), InterMesh 7707 Fire Subscriber (All versions \u003c V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The affected devices contain a SUID binary that could allow an authenticated local attacker to execute arbitrary commands with root privileges.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Privilege escalation in InterMesh 7177 Hybrid 2.0 Subscriber","id":"CVE-2024-47904","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Memory corruption in Connect Secure","id":"CVE-2024-47905"},"packages":[],"prev":{"headline":"File upload in InterMesh 7177 Hybrid 2.0 Subscriber","id":"CVE-2024-47903"},"products":["InterMesh 7177 Hybrid 2.0 Subscriber","InterMesh 7707 Fire Subscriber"],"published":"2024-10-23","related":[{"cvss_score":10,"headline":"Command injection in InterMesh 7177 Hybrid 2.0 Subscriber","id":"CVE-2024-47901","kev_date_added":null,"published":"2024-10-23"},{"cvss_score":6.9,"headline":"Missing authorization in InterMesh 7177 Hybrid 2.0 Subscriber","id":"CVE-2024-47902","kev_date_added":null,"published":"2024-10-23"},{"cvss_score":6.9,"headline":"File upload in InterMesh 7177 Hybrid 2.0 Subscriber","id":"CVE-2024-47903","kev_date_added":null,"published":"2024-10-23"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-10-23","vendors":["Siemens"]},"summary":"An authenticated local attacker can exploit a SUID binary to execute arbitrary commands with root privileges on Siemens InterMesh subscriber devices.","url":"https://insights.sbomify.com/CVE-2024-47904/"}