{"answers":{"affected":"","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-48455 exists.","fix":"No fix has been published for CVE-2024-48455 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-48455 is a low-severity vulnerability in n/a, published on 6 Jan 2025. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-48455 and fix it if it is affected.\n\nWhat it is: CVE-2024-48455 is a low-severity vulnerability in n/a, published on 6 Jan 2025. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-48455 exists.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-48455/ (Markdown: https://insights.sbomify.com/CVE-2024-48455/index.md)","id":"CVE-2024-48455","markdown":"https://insights.sbomify.com/CVE-2024-48455/index.md","name":"CVE-2024-48455","record":{"aliases":["GHSA-jhc7-3m5f-4pm9"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Netis WiFi router","requires_auth":"high_privilege","summary":"Remote attackers can obtain sensitive information from Netis WiFi routers via specific parameters in the skk_get.cgi component.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[],"cvss":{"score":2.7,"severity":"low","source":"cisa-adp","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[],"description":"An issue in Netis Wifi6 Router NX10 2.0.1.3643 and 2.0.1.3582 and Netis Wifi 11AC Router NC65 3.0.0.3749 and Netis Wifi 11AC Router NC63 3.0.0.3327 and 3.0.0.3503 and Netis Wifi 11AC Router NC21 3.0.0.3800, 3.0.0.3500 and 3.0.0.3329 and Netis Wifi Router MW5360 1.0.1.3442 and 1.0.1.3031 allows a remote attacker to obtain sensitive information via the mode_name, wl_link parameters of the skk_get.cgi component.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":"2024-12-27","github_poc":0,"max_poc_stars":null,"metasploit":1,"nuclei":1,"refs":[{"date":"2024-12-27","kind":"metasploit","ref":"exploit/linux/http/netis_unauth_rce_cve_2024_48456_and_48457","stars":null,"title":"Netis Router Exploit Chain Reactor (CVE-2024-48455, CVE-2024-48456 and CVE-2024-48457)."},{"date":null,"kind":"nuclei","ref":"http/cves/2024/CVE-2024-48455.yaml","stars":null,"title":"Netis Wifi Router - Information Disclosure"}],"tier":"weaponised"},"has_fix":null,"headline":"Information disclosure in n/a","id":"CVE-2024-48455","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in n/a","id":"CVE-2024-48456"},"packages":[],"prev":{"headline":"File upload in n/a","id":"CVE-2024-48454"},"products":["n/a"],"published":"2025-01-06","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"attribution","licence":"BSD-3-Clause","name":"Metasploit"},{"class":"attribution","licence":"MIT","name":"Nuclei templates"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-01-07","vendors":["n/a"]},"summary":"Remote attackers can obtain sensitive information from Netis WiFi routers via specific parameters in the skk_get.cgi component.","url":"https://insights.sbomify.com/CVE-2024-48455/"}