{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-48966 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-48966 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-48966 is a critical missing authorization vulnerability in Baxter Life2000 Ventilation System, published on 14 Nov 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-48966 and fix it if it is affected.\n\nWhat it is: CVE-2024-48966 is a critical missing authorization vulnerability in Baxter Life2000 Ventilation System, published on 14 Nov 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-48966 in the wild and no public exploit code.\n\nAffected product: Baxter Life2000 Ventilation System. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-48966/ (Markdown: https://insights.sbomify.com/CVE-2024-48966/index.md)","id":"CVE-2024-48966","markdown":"https://insights.sbomify.com/CVE-2024-48966/index.md","name":"CVE-2024-48966","record":{"aliases":["GHSA-285j-vfp9-5w9w"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Medical ventilator","requires_auth":"none","summary":"Service tools for Life2000 ventilators lack authentication, allowing local attackers to access diagnostics or modify device settings without credentials.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Baxter","cpe":[],"cvss":{"score":10,"severity":"critical","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"The software tools used by service personnel to test \u0026 calibrate the ventilator do not support user authentication. An attacker with access to the Service PC where the tools are installed could obtain diagnostic information through the test tool or manipulate the ventilator's settings and embedded software via the calibration tool, without having to authenticate to either tool. This could result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Life2000 service tools for test and calibration do not support user authentication","id":"CVE-2024-48966","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Life2000 ventilator and Service PC lack sufficient audit logging capabilities","id":"CVE-2024-48967"},"packages":[],"prev":{"headline":"OS Command Injection in Snyk gradle plugin","id":"CVE-2024-48964"},"products":["Life2000 Ventilation System"],"published":"2024-11-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-11-15","vendors":["Baxter"]},"summary":"Service tools for Life2000 ventilators lack authentication, allowing local attackers to access diagnostics or modify device settings without credentials.","url":"https://insights.sbomify.com/CVE-2024-48966/"}