{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-48971 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-48971 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-48971 is a critical vulnerability in Baxter Life2000 Ventilation System, published on 14 Nov 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-48971 and fix it if it is affected.\n\nWhat it is: CVE-2024-48971 is a critical vulnerability in Baxter Life2000 Ventilation System, published on 14 Nov 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-48971 in the wild and no public exploit code.\n\nAffected product: Baxter Life2000 Ventilation System. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-48971/ (Markdown: https://insights.sbomify.com/CVE-2024-48971/index.md)","id":"CVE-2024-48971","markdown":"https://insights.sbomify.com/CVE-2024-48971/index.md","name":"CVE-2024-48971","record":{"aliases":["GHSA-78wf-p97g-f4jr"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["privilege_escalation","account_takeover"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Medical ventilator","requires_auth":"none","summary":"Hardcoded clinician passwords in the Life2000 Ventilator allow attackers to gain unauthorized access with elevated privileges.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Baxter","cpe":[],"cvss":{"score":9.3,"severity":"critical","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"}],"description":"The Clinician Password and Serial Number Clinician Password are hard-coded into the ventilator in plaintext form. This could allow an attacker to obtain the password off the ventilator and use it to gain unauthorized access to the device, with clinician privileges.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Clinician Password and Serial Number Clinician Password are hard-coded in Life2000 Ventilator","id":"CVE-2024-48971","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Debug port on Life2000 Ventilator serial interface is enabled by default","id":"CVE-2024-48973"},"packages":[],"prev":{"headline":"Life2000 Ventilator microcontroller lacks memory protection","id":"CVE-2024-48970"},"products":["Life2000 Ventilation System"],"published":"2024-11-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-11-15","vendors":["Baxter"]},"summary":"Hardcoded clinician passwords in the Life2000 Ventilator allow attackers to gain unauthorized access with elevated privileges.","url":"https://insights.sbomify.com/CVE-2024-48971/"}