{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-48973 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-48973 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-48973 is a critical vulnerability in Baxter Life2000 Ventilation System, published on 14 Nov 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-48973 and fix it if it is affected.\n\nWhat it is: CVE-2024-48973 is a critical vulnerability in Baxter Life2000 Ventilation System, published on 14 Nov 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-48973 in the wild and no public exploit code.\n\nAffected product: Baxter Life2000 Ventilation System. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-48973/ (Markdown: https://insights.sbomify.com/CVE-2024-48973/index.md)","id":"CVE-2024-48973","markdown":"https://insights.sbomify.com/CVE-2024-48973/index.md","name":"CVE-2024-48973","record":{"aliases":["GHSA-xx59-963p-2v9w"],"analysis":{"component_type":"iot_embedded","fix_type":"configuration_change","impacts":["data_read","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Medical ventilator","requires_auth":"none","summary":"Attackers can access unencrypted debug ports on Life2000 ventilators to disclose information or alter device settings due to default configurations.","user_interaction":"not_required","vuln_class":"misconfiguration"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Baxter","cpe":[],"cvss":{"score":9.3,"severity":"critical","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-1263","name":"Improper Physical Access Control"}],"description":"The debug port on the ventilator's serial interface is enabled by default. This could allow an attacker to send and receive messages over the debug port (which are unencrypted; see 3.2.1) that result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Debug port on Life2000 Ventilator serial interface is enabled by default","id":"CVE-2024-48973","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"misconfiguration","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Life2000 Ventilator does not perform proper file integrity checks when adopting firmware updates","id":"CVE-2024-48974"},"packages":[],"prev":{"headline":"Clinician Password and Serial Number Clinician Password are hard-coded in Life2000 Ventilator","id":"CVE-2024-48971"},"products":["Life2000 Ventilation System"],"published":"2024-11-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-11-18","vendors":["Baxter"]},"summary":"Attackers can access unencrypted debug ports on Life2000 ventilators to disclose information or alter device settings due to default configurations.","url":"https://insights.sbomify.com/CVE-2024-48973/"}