{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-48974 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-48974 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-48974 is a critical vulnerability in Baxter Life2000 Ventilation System, published on 14 Nov 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-48974 and fix it if it is affected.\n\nWhat it is: CVE-2024-48974 is a critical vulnerability in Baxter Life2000 Ventilation System, published on 14 Nov 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-48974 in the wild and no public exploit code.\n\nAffected product: Baxter Life2000 Ventilation System. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-48974/ (Markdown: https://insights.sbomify.com/CVE-2024-48974/index.md)","id":"CVE-2024-48974","markdown":"https://insights.sbomify.com/CVE-2024-48974/index.md","name":"CVE-2024-48974","record":{"aliases":["GHSA-rfvx-872w-6rpr"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["code_execution","data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Medical ventilator","requires_auth":"none","summary":"Attackers can push compromised firmware to the Life2000 Ventilator due to missing integrity checks, potentially disrupting device function or disclosing information.","user_interaction":"not_required","vuln_class":"other"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Baxter","cpe":[],"cvss":{"score":9.3,"severity":"critical","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-494","name":"Download of Code Without Integrity Check"}],"description":"The ventilator does not perform proper file integrity checks when adopting firmware updates. This makes it possible for an attacker to force unauthorized changes to the device's configuration settings and/or compromise device functionality by pushing a compromised/illegitimate firmware file. This could disrupt the function of the device and/or cause unauthorized information disclosure.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Life2000 Ventilator does not perform proper file integrity checks when adopting firmware updates","id":"CVE-2024-48974","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"other","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Memory corruption in n/a","id":"CVE-2024-48981"},"packages":[],"prev":{"headline":"Debug port on Life2000 Ventilator serial interface is enabled by default","id":"CVE-2024-48973"},"products":["Life2000 Ventilation System"],"published":"2024-11-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-11-18","vendors":["Baxter"]},"summary":"Attackers can push compromised firmware to the Life2000 Ventilator due to missing integrity checks, potentially disrupting device function or disclosing information.","url":"https://insights.sbomify.com/CVE-2024-48974/"}