{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-48989 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-48989 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-48989 is a high-severity denial of service vulnerability in Bosch Rexroth AG IndraDrive FWA-INDRV*-MP*, published on 13 Nov 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-48989 and fix it if it is affected.\n\nWhat it is: CVE-2024-48989 is a high-severity denial of service vulnerability in Bosch Rexroth AG IndraDrive FWA-INDRV*-MP*, published on 13 Nov 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-48989 in the wild and no public exploit code.\n\nAffected product: Bosch Rexroth AG IndraDrive FWA-INDRV*-MP*. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-48989/ (Markdown: https://insights.sbomify.com/CVE-2024-48989/index.md)","id":"CVE-2024-48989","markdown":"https://insights.sbomify.com/CVE-2024-48989/index.md","name":"CVE-2024-48989","record":{"aliases":["GHSA-w26w-xhj2-cfxj"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Industrial Drive Controller","requires_auth":"none","summary":"An attacker can cause a denial of service on Bosch Rexroth IndraDrive devices by sending arbitrary UDP messages, rendering the industrial controller unresponsive.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"bosch","cpe":[],"cvss":{"score":7.5,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-770","name":"Allocation of Resources Without Limits or Throttling"},{"id":"CWE-400","name":"Uncontrolled Resource Consumption"}],"description":"A vulnerability in the PROFINET stack implementation of the IndraDrive (all versions) of Bosch Rexroth allows an attacker to cause a denial of service, rendering the device unresponsive by sending arbitrary UDP messages.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Denial of service in IndraDrive FWA-INDRV*-MP*","id":"CVE-2024-48989","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Code injection in needrestart","id":"CVE-2024-48990"},"packages":[],"prev":{"headline":"Apache StreamPark: SQL injection vulnerability","id":"CVE-2024-48988"},"products":["IndraDrive FWA-INDRV*-MP*"],"published":"2024-11-13","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-11-13","vendors":["Bosch Rexroth AG"]},"summary":"An attacker can cause a denial of service on Bosch Rexroth IndraDrive devices by sending arbitrary UDP messages, rendering the industrial controller unresponsive.","url":"https://insights.sbomify.com/CVE-2024-48989/"}