{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-49501 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-49501 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-49501 is a medium-severity missing authorization vulnerability in OMRON Corporation SYSMAC-SE2[][][], published on 1 Nov 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-49501 and fix it if it is affected.\n\nWhat it is: CVE-2024-49501 is a medium-severity missing authorization vulnerability in OMRON Corporation SYSMAC-SE2[][][], published on 1 Nov 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-49501 in the wild and no public exploit code.\n\nAffected product: OMRON Corporation SYSMAC-SE2[][][]. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-49501/ (Markdown: https://insights.sbomify.com/CVE-2024-49501/index.md)","id":"CVE-2024-49501","markdown":"https://insights.sbomify.com/CVE-2024-49501/index.md","name":"CVE-2024-49501","record":{"aliases":["GHSA-3q3m-hfjx-w733"],"analysis":{"component_type":"desktop_application","fix_type":"patch","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Industrial automation software","requires_auth":"none","summary":"An attacker can bypass data protection to access protected programs in OMRON Sysmac Studio, exposing sensitive industrial control logic.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"jpcert","cpe":[],"cvss":{"score":5.7,"severity":"medium","source":"cna","vector":"CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:N","version":"3.0"},"cwes":[{"id":"CWE-863","name":"Incorrect Authorization"}],"description":"Sysmac Studio provided by OMRON Corporation contains an incorrect authorization vulnerability. If this vulnerability is exploited, an attacker may access the program which is protected by Data Protection function.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in SYSMAC-SE2[][][]","id":"CVE-2024-49501","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2024"},"n_packages":0,"n_references":3,"next":{"headline":"Reflected XSS in Setup Wizard, HTTP Proxy credentials pane in spacewalk-web","id":"CVE-2024-49502"},"packages":[],"prev":{"headline":"Security feature bypass in Samsung Mobile Devices","id":"CVE-2024-49422"},"products":["SYSMAC-SE2[][][]"],"published":"2024-11-01","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-11-01","vendors":["OMRON Corporation"]},"summary":"An attacker can bypass data protection to access protected programs in OMRON Sysmac Studio, exposing sensitive industrial control logic.","url":"https://insights.sbomify.com/CVE-2024-49501/"}