{"answers":{"affected":"It affects 3 products.","exploited":"There is no known exploitation of CVE-2024-50358 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-50358 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-50358 is a high-severity vulnerability in Advantech EKI-6333AC-1GPO, published on 26 Nov 2024. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-50358 and fix it if it is affected.\n\nWhat it is: CVE-2024-50358 is a high-severity vulnerability in Advantech EKI-6333AC-1GPO, published on 26 Nov 2024. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-50358 in the wild and no public exploit code.\n\nAffected product: Advantech EKI-6333AC-1GPO. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-50358/ (Markdown: https://insights.sbomify.com/CVE-2024-50358/index.md)","id":"CVE-2024-50358","markdown":"https://insights.sbomify.com/CVE-2024-50358/index.md","name":"CVE-2024-50358","record":{"aliases":["GHSA-mfqv-qjxh-rprm"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["privilege_escalation","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Advantech industrial switch","requires_auth":"high_privilege","summary":"Authenticated attackers can restore tampered configuration backups on Advantech industrial switches to bypass security controls or escalate privileges.","user_interaction":"not_required","vuln_class":"misconfiguration"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Nozomi","cpe":[{"product":"eki-6333ac-1gpo_firmware","vendor":"advantech"},{"product":"eki-6333ac-2g_firmware","vendor":"advantech"},{"product":"eki-6333ac-2gd_firmware","vendor":"advantech"}],"cvss":{"score":7.2,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-15","name":"External Control of System or Configuration Setting"}],"description":"A CWE-15 \"External Control of System or Configuration Setting\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The vulnerability can be exploited by authenticated users by restoring a tampered configuration backup.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Misconfiguration in EKI-6333AC-1GPO","id":"CVE-2024-50358","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"misconfiguration","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Command injection in EKI-6333AC-1GPO","id":"CVE-2024-50359"},"packages":[],"prev":{"headline":"Misconfiguration in FutureNet NXR-G050 series","id":"CVE-2024-50357"},"products":["EKI-6333AC-1GPO","EKI-6333AC-2G","EKI-6333AC-2GD"],"published":"2024-11-26","related":[{"cvss_score":9.8,"headline":"Command injection in EKI-6333AC-1GPO","id":"CVE-2024-50370","kev_date_added":null,"published":"2024-11-26"},{"cvss_score":9.8,"headline":"Command injection in EKI-6333AC-1GPO","id":"CVE-2024-50371","kev_date_added":null,"published":"2024-11-26"},{"cvss_score":9.8,"headline":"Command injection in EKI-6333AC-1GPO","id":"CVE-2024-50372","kev_date_added":null,"published":"2024-11-26"},{"cvss_score":9.8,"headline":"Command injection in EKI-6333AC-1GPO","id":"CVE-2024-50373","kev_date_added":null,"published":"2024-11-26"},{"cvss_score":9.8,"headline":"Command injection in EKI-6333AC-1GPO","id":"CVE-2024-50374","kev_date_added":null,"published":"2024-11-26"},{"cvss_score":9.8,"headline":"Missing authorization in EKI-6333AC-1GPO","id":"CVE-2024-50375","kev_date_added":null,"published":"2024-11-26"},{"cvss_score":7.3,"headline":"Cross-site scripting in EKI-6333AC-1GPO","id":"CVE-2024-50376","kev_date_added":null,"published":"2024-11-26"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-11-26","vendors":["Advantech"]},"summary":"Authenticated attackers can restore tampered configuration backups on Advantech industrial switches to bypass security controls or escalate privileges.","url":"https://insights.sbomify.com/CVE-2024-50358/"}