{"answers":{"affected":"It affects 3 products.","exploited":"There is no known exploitation of CVE-2024-50377 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-50377 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-50377 is a medium-severity vulnerability in Advantech EKI-6333AC-1GPO, published on 26 Nov 2024. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2024-50377 and fix it if it is affected.\n\nWhat it is: CVE-2024-50377 is a medium-severity vulnerability in Advantech EKI-6333AC-1GPO, published on 26 Nov 2024. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2024-50377 in the wild and no public exploit code.\n\nAffected product: Advantech EKI-6333AC-1GPO. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-50377/ (Markdown: https://insights.sbomify.com/CVE-2024-50377/index.md)","id":"CVE-2024-50377","markdown":"https://insights.sbomify.com/CVE-2024-50377/index.md","name":"CVE-2024-50377","record":{"aliases":["GHSA-vjgf-5h8j-h29j"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["data_read","security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Advantech industrial switch","requires_auth":"high_privilege","summary":"Attackers can decrypt backup configuration archives using a static password to access sensitive device settings on Advantech industrial switches.","user_interaction":"required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Nozomi","cpe":[{"product":"eki-6333ac-1gpo_firmware","vendor":"advantech"},{"product":"eki-6333ac-2g_firmware","vendor":"advantech"},{"product":"eki-6333ac-2gd_firmware","vendor":"advantech"}],"cvss":{"score":6.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"},{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"description":"A CWE-798 \"Use of Hard-coded Credentials\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The vulnerability is associated to the backup configuration functionality that by default encrypts the archives using a static password.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in EKI-6333AC-1GPO","id":"CVE-2024-50377","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Apache Airflow: Secrets not masked in UI when sensitive variables are set via Airflow cli","id":"CVE-2024-50378"},"packages":[],"prev":{"headline":"Cross-site scripting in EKI-6333AC-1GPO","id":"CVE-2024-50376"},"products":["EKI-6333AC-1GPO","EKI-6333AC-2G","EKI-6333AC-2GD"],"published":"2024-11-26","related":[{"cvss_score":9.8,"headline":"Command injection in EKI-6333AC-1GPO","id":"CVE-2024-50370","kev_date_added":null,"published":"2024-11-26"},{"cvss_score":9.8,"headline":"Command injection in EKI-6333AC-1GPO","id":"CVE-2024-50371","kev_date_added":null,"published":"2024-11-26"},{"cvss_score":9.8,"headline":"Command injection in EKI-6333AC-1GPO","id":"CVE-2024-50372","kev_date_added":null,"published":"2024-11-26"},{"cvss_score":9.8,"headline":"Command injection in EKI-6333AC-1GPO","id":"CVE-2024-50373","kev_date_added":null,"published":"2024-11-26"},{"cvss_score":9.8,"headline":"Command injection in EKI-6333AC-1GPO","id":"CVE-2024-50374","kev_date_added":null,"published":"2024-11-26"},{"cvss_score":9.8,"headline":"Missing authorization in EKI-6333AC-1GPO","id":"CVE-2024-50375","kev_date_added":null,"published":"2024-11-26"},{"cvss_score":7.3,"headline":"Cross-site scripting in EKI-6333AC-1GPO","id":"CVE-2024-50376","kev_date_added":null,"published":"2024-11-26"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-11-26","vendors":["Advantech"]},"summary":"Attackers can decrypt backup configuration archives using a static password to access sensitive device settings on Advantech industrial switches.","url":"https://insights.sbomify.com/CVE-2024-50377/"}