CVE-2024-50557 Command injection in RUGGEDCOM RM1224 LTE(4G) EU

High 8.6 Published Updated

Unauthenticated remote attackers can execute arbitrary code on Siemens SCALANCE routers due to improper input validation in iperf configuration fields.

Exploited in the wild
Not known
Login needed
An administrator
Attackable
Over the internet
Victim action needed
Not needed
Fix
None listed

What is CVE-2024-50557?

CVE-2024-50557 is a high-severity command injection vulnerability in Siemens RUGGEDCOM RM1224 LTE(4G) EU, published on 12 Nov 2024. An attacker needs administrator access to exploit it, with no action from the victim.

Official description

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.2). Affected devices do not properly validate input in configuration fields of the iperf functionality. This could allow an unauthenticated remote attacker to execute arbitrary code on the device.

Weakness: CWE-20

Which versions are affected by CVE-2024-50557?

It affects 26 products.

Products include Siemens Ruggedcom Rm1224 Lte\(4g\) Eu Firmware, Siemens Ruggedcom Rm1224 Lte\(4g\) Nam Firmware, Siemens Scalance M804pb Firmware, Siemens Scalance M812-1 \(Annex A\) Firmware, Siemens Scalance M812-1 \(Annex B\) Firmware, Siemens Scalance M816-1 \(Annex A\) Firmware and 20 more.

How do I fix CVE-2024-50557?

No fix has been published for CVE-2024-50557 yet. Limit exposure of the affected software until one is available.

Upgrade, and pass arguments to programs as a list instead of through a shell. More about Command injection.

Is CVE-2024-50557 being exploited?

There is no known exploitation of CVE-2024-50557 in the wild and no public exploit code.

Sources

Also known as GHSA-7679-9xw6-2858.

Is CVE-2024-50557 in your software?

Upload an SBOM and sbomify checks it against every vulnerability here, every day.

Check your SBOMs for free