CVE-2024-50561 Cross-site scripting in RUGGEDCOM RM1224 LTE(4G) EU

Medium 5.1 Published Updated

An attacker can inject malicious scripts into the web interface of Siemens SCALANCE routers, potentially bypassing security controls.

Exploited in the wild
Not known
Login needed
Not needed
Attackable
Over the internet
Victim action needed
A user has to click or open something
Fix
None listed

What is CVE-2024-50561?

CVE-2024-50561 is a medium-severity cross-site scripting vulnerability in Siemens RUGGEDCOM RM1224 LTE(4G) EU, published on 12 Nov 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.

Official description

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices do not properly sanitize the filenames before uploading. This could allow an authenticated remote attacker to compromise of integrity of the system.

Weakness: CWE-79

Which versions are affected by CVE-2024-50561?

It affects 26 products.

Products include Siemens Ruggedcom Rm1224 Lte\(4g\) Eu Firmware, Siemens Ruggedcom Rm1224 Lte\(4g\) Nam Firmware, Siemens Scalance M804pb Firmware, Siemens Scalance M812-1 \(Annex A\) Firmware, Siemens Scalance M812-1 \(Annex B\) Firmware, Siemens Scalance M816-1 \(Annex A\) Firmware and 20 more.

How do I fix CVE-2024-50561?

No fix has been published for CVE-2024-50561 yet. Limit exposure of the affected software until one is available.

Escape output for the context it lands in and set a strict Content Security Policy. Upgrading the affected component is the real fix. More about Cross-site scripting.

Is CVE-2024-50561 being exploited?

There is no known exploitation of CVE-2024-50561 in the wild and no public exploit code.

Sources

Also known as GHSA-fc63-6853-v5m2.

Is CVE-2024-50561 in your software?

Upload an SBOM and sbomify checks it against every vulnerability here, every day.

Check your SBOMs for free