{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-51074 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-51074 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-51074 is a medium-severity missing authorization vulnerability in n/a, published on 22 Nov 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-51074 and fix it if it is affected.\n\nWhat it is: CVE-2024-51074 is a medium-severity missing authorization vulnerability in n/a, published on 22 Nov 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-51074 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-51074/ (Markdown: https://insights.sbomify.com/CVE-2024-51074/index.md)","id":"CVE-2024-51074","markdown":"https://insights.sbomify.com/CVE-2024-51074/index.md","name":"CVE-2024-51074","record":{"aliases":["GHSA-pfcx-5c23-m8c6"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Vehicle instrument cluster","requires_auth":"none","summary":"Attackers with CAN bus access can arbitrarily modify odometer readings in KIA Seltos vehicles due to incorrect access control in the instrument cluster.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[],"cvss":{"score":6.7,"severity":"medium","source":"cisa-adp","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:H","version":"3.1"},"cwes":[],"description":"Incorrect access control in KIA Seltos vehicle instrument cluster with software and hardware v1.0 allows attackers to arbitrarily change odometer readings in the vehicle by targeting the instrument cluster through the unsecured CAN network. NOTE: this is disputed by the supplier because the CAN bus is not externally exposed, and because the packets can only increase the odometer reading (which typically has no value to an adversary). Also, this is disputed by the Supplier because the findings came from a potentially unrealistic test environment (an isolated ECU part that was not in a vehicle), and because the observed behavior follows the UDS (Unified Diagnostic Services) specification.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in n/a","id":"CVE-2024-51074","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2024"},"n_packages":0,"n_references":2,"next":{"headline":"Cross-site scripting in n/a","id":"CVE-2024-51075"},"packages":[],"prev":{"headline":"Other in n/a","id":"CVE-2024-51073"},"products":["n/a"],"published":"2024-11-22","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-01-13","vendors":["n/a"]},"summary":"Attackers with CAN bus access can arbitrarily modify odometer readings in KIA Seltos vehicles due to incorrect access control in the instrument cluster.","url":"https://insights.sbomify.com/CVE-2024-51074/"}