{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-51407 exists.","fix":"No fix has been published for CVE-2024-51407 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-51407 is a medium-severity vulnerability in n/a, published on 1 Nov 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-51407 and fix it if it is affected.\n\nWhat it is: CVE-2024-51407 is a medium-severity vulnerability in n/a, published on 1 Nov 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-51407 exists.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-51407/ (Markdown: https://insights.sbomify.com/CVE-2024-51407/index.md)","id":"CVE-2024-51407","markdown":"https://insights.sbomify.com/CVE-2024-51407/index.md","name":"CVE-2024-51407","record":{"aliases":["GHSA-v29w-7hpp-g74c"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["other"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"SDN OpenFlow Controller","requires_auth":"none","summary":"Local hosts can construct false broadcast ports in Floodlight SDN Controller, causing inter-host communication anomalies.","user_interaction":"not_required","vuln_class":"business_logic"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"floodlight","vendor":"projectfloodlight"}],"cvss":{"score":6.2,"severity":"medium","source":"cisa-adp","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[],"description":"Floodlight SDN OpenFlow Controller v.1.2 has an issue that allows local hosts to construct false broadcast ports causing inter-host communication anomalies.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":false,"headline":"Business logic in n/a","id":"CVE-2024-51407","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"business_logic","year":"2024"},"n_packages":0,"n_references":3,"next":{"headline":"Server-side request forgery in n/a","id":"CVE-2024-51408"},"packages":[],"prev":{"headline":"Other in n/a","id":"CVE-2024-51406"},"products":["n/a"],"published":"2024-11-01","related":[{"cvss_score":6.1,"headline":"Cross-site scripting in n/a","id":"CVE-2018-1000163","kev_date_added":null,"published":"2018-04-18"},{"cvss_score":5.5,"headline":"Denial of service in n/a","id":"CVE-2024-57672","kev_date_added":null,"published":"2025-02-06"},{"cvss_score":5.5,"headline":"Denial of service in n/a","id":"CVE-2024-57673","kev_date_added":null,"published":"2025-02-06"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-11-04","vendors":["n/a"]},"summary":"Local hosts can construct false broadcast ports in Floodlight SDN Controller, causing inter-host communication anomalies.","url":"https://insights.sbomify.com/CVE-2024-51407/"}