{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-52335 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-52335 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-52335 is a critical SQL injection vulnerability in Siemens syngo.plaza VB30E, published on 6 Dec 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-52335 and fix it if it is affected.\n\nWhat it is: CVE-2024-52335 is a critical SQL injection vulnerability in Siemens syngo.plaza VB30E, published on 6 Dec 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-52335 in the wild and no public exploit code.\n\nAffected product: Siemens syngo.plaza VB30E. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-52335/ (Markdown: https://insights.sbomify.com/CVE-2024-52335/index.md)","id":"CVE-2024-52335","markdown":"https://insights.sbomify.com/CVE-2024-52335/index.md","name":"CVE-2024-52335","record":{"aliases":["GHSA-mj32-rr2c-j468"],"analysis":{"component_type":"server_software","fix_type":"patch","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Medical imaging software","requires_auth":"none","summary":"An attacker with application access can execute malicious SQL commands to compromise the database due to improper input sanitization.","user_interaction":"not_required","vuln_class":"sql_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":9.3,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-89","name":"Improper Neutralization of Special Elements used in an SQL Command"}],"description":"A vulnerability has been identified in syngo.plaza VB30E (All versions \u003c VB30E_HF05). The affected application do not properly sanitize input data before sending it to the SQL server. This could allow an attacker with access to the application could use this vulnerability to execute malicious SQL commands to compromise the whole database.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"SQL injection in syngo.plaza VB30E","id":"CVE-2024-52335","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"sql_injection","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Tuned: `script_pre` and `script_post` options allow to pass arbitrary scripts executed by root","id":"CVE-2024-52336"},"packages":[],"prev":{"headline":"Weak cryptography in syngo.plaza VB30E","id":"CVE-2024-52334"},"products":["syngo.plaza VB30E"],"published":"2024-12-06","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-12-06","vendors":["Siemens"]},"summary":"An attacker with application access can execute malicious SQL commands to compromise the database due to improper input sanitization.","url":"https://insights.sbomify.com/CVE-2024-52335/"}