{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-5313 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-5313 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-5313 is a medium-severity vulnerability in Schneider Electric EVlink Home Smart, published on 12 Jun 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-5313 and fix it if it is affected.\n\nWhat it is: CVE-2024-5313 is a medium-severity vulnerability in Schneider Electric EVlink Home Smart, published on 12 Jun 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-5313 in the wild and no public exploit code.\n\nAffected product: Schneider Electric EVlink Home Smart. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-5313/ (Markdown: https://insights.sbomify.com/CVE-2024-5313/index.md)","id":"CVE-2024-5313","markdown":"https://insights.sbomify.com/CVE-2024-5313/index.md","name":"CVE-2024-5313","record":{"aliases":["GHSA-w3vp-r637-3fhj"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_read","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"EV charging station","requires_auth":"none","summary":"Exposes SSH interface on network, allowing port scanning, fingerprinting, and potential denial of service attacks against the charging station.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"evlink_home_firmware","vendor":"schneider-electric"}],"cvss":{"score":6.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L","version":"3.1"},"cwes":[{"id":"CWE-668","name":"Exposure of Resource to Wrong Sphere"}],"description":"CWE-668: Exposure of the Resource Wrong Sphere vulnerability exists that exposes a SSH\ninterface over the product network interface. This does not allow to directly exploit the product or\nmake any unintended operation as the SSH interface access is protected by an authentication\nmechanism. Impacts are limited to port scanning and fingerprinting activities as well as attempts\nto perform a potential denial of service attack on the exposed SSH interface.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in EVlink Home Smart","id":"CVE-2024-5313","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Multiple vulnerabilities in DOLIBARR's ERP CMS","id":"CVE-2024-5314"},"packages":[],"prev":{"headline":"Cross-Site Scripting vulnerability in PHP Server Monitor","id":"CVE-2024-5312"},"products":["EVlink Home Smart"],"published":"2024-06-12","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-01","vendors":["Schneider Electric"]},"summary":"Exposes SSH interface on network, allowing port scanning, fingerprinting, and potential denial of service attacks against the charging station.","url":"https://insights.sbomify.com/CVE-2024-5313/"}