{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-53649 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-53649 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-53649 is a high-severity vulnerability in Siemens SIPROTEC 5 6MD84 (CP300), published on 14 Jan 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-53649 and fix it if it is affected.\n\nWhat it is: CVE-2024-53649 is a high-severity vulnerability in Siemens SIPROTEC 5 6MD84 (CP300), published on 14 Jan 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-53649 in the wild and no public exploit code.\n\nAffected product: Siemens SIPROTEC 5 6MD84 (CP300). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-53649/ (Markdown: https://insights.sbomify.com/CVE-2024-53649/index.md)","id":"CVE-2024-53649","markdown":"https://insights.sbomify.com/CVE-2024-53649/index.md","name":"CVE-2024-53649","record":{"aliases":["GHSA-9xg2-78h5-2f5f"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SIPROTEC 5","requires_auth":"low_privilege","summary":"An attacker can access sensitive information from Siemens SIPROTEC 5 devices due to improper file permissions, potentially exposing configuration or operational data.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":7.1,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-552","name":"Files or Directories Accessible to External Parties"}],"description":"A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions \u003c V9.80), SIPROTEC 5 6MD85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 6MD86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 6MD89 (CP300) (All versions \u003e= V7.80 \u003c V9.68), SIPROTEC 5 6MU85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7KE85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SA82 (CP100) (All versions \u003e= V7.80 \u003c V8.90), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SA86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SA87 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SD82 (CP100) (All versions \u003e= V7.80 \u003c V8.90), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SD86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SD87 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SJ81 (CP100) (All versions \u003e= V7.80 \u003c V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SJ82 (CP100) (All versions \u003e= V7.80 \u003c V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SJ85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SJ86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SK82 (CP100) (All versions \u003e= V7.80 \u003c V8.90), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SK85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SL82 (CP100) (All versions \u003e= V7.80 \u003c V8.90), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SL86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SL87 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7SS85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7ST85 (CP300) (All versions \u003c V9.68), SIPROTEC 5 7ST86 (CP300) (All versions \u003c V9.80), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7SX85 (CP300) (All versions \u003c V9.80), SIPROTEC 5 7SY82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7UM85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7UT82 (CP100) (All versions \u003e= V7.80 \u003c V8.90), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V9.80), SIPROTEC 5 7UT85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7UT86 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7UT87 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7VE85 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7VK87 (CP300) (All versions \u003e= V7.80 \u003c V9.80), SIPROTEC 5 7VU85 (CP300) (All versions \u003c V9.80), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003c V9.80). Affected devices do not properly limit the path accessible via their webserver.  This could allow an authenticated remote attacker to read arbitrary files from the filesystem of affected devices.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in SIPROTEC 5 6MD84 (CP300)","id":"CVE-2024-53649","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in SIPROTEC 5 6MD84 (CP300)","id":"CVE-2024-53651"},"packages":[],"prev":{"headline":"Other in SIPROTEC 5 6MD84 (CP300)","id":"CVE-2024-53648"},"products":["SIPROTEC 5 6MD84 (CP300)","SIPROTEC 5 6MD85 (CP300)","SIPROTEC 5 6MD86 (CP300)","SIPROTEC 5 6MD89 (CP300)","SIPROTEC 5 6MU85 (CP300)","SIPROTEC 5 7KE85 (CP300)","SIPROTEC 5 7SA82 (CP100)","SIPROTEC 5 7SA82 (CP150)","SIPROTEC 5 7SA86 (CP300)","SIPROTEC 5 7SA87 (CP300)","SIPROTEC 5 7SD82 (CP100)","SIPROTEC 5 7SD82 (CP150)","SIPROTEC 5 7SD86 (CP300)","SIPROTEC 5 7SD87 (CP300)","SIPROTEC 5 7SJ81 (CP100)","SIPROTEC 5 7SJ81 (CP150)","SIPROTEC 5 7SJ82 (CP100)","SIPROTEC 5 7SJ82 (CP150)","SIPROTEC 5 7SJ85 (CP300)","SIPROTEC 5 7SJ86 (CP300)","SIPROTEC 5 7SK82 (CP100)","SIPROTEC 5 7SK82 (CP150)","SIPROTEC 5 7SK85 (CP300)","SIPROTEC 5 7SL82 (CP100)","SIPROTEC 5 7SL82 (CP150)","SIPROTEC 5 7SL86 (CP300)","SIPROTEC 5 7SL87 (CP300)","SIPROTEC 5 7SS85 (CP300)","SIPROTEC 5 7ST85 (CP300)","SIPROTEC 5 7ST86 (CP300)","SIPROTEC 5 7SX82 (CP150)","SIPROTEC 5 7SX85 (CP300)","SIPROTEC 5 7SY82 (CP150)","SIPROTEC 5 7UM85 (CP300)","SIPROTEC 5 7UT82 (CP100)","SIPROTEC 5 7UT82 (CP150)","SIPROTEC 5 7UT85 (CP300)","SIPROTEC 5 7UT86 (CP300)","SIPROTEC 5 7UT87 (CP300)","SIPROTEC 5 7VE85 (CP300)","SIPROTEC 5 7VK87 (CP300)","SIPROTEC 5 7VU85 (CP300)","SIPROTEC 5 Compact 7SX800 (CP050)"],"published":"2025-01-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-11-11","vendors":["Siemens"]},"summary":"An attacker can access sensitive information from Siemens SIPROTEC 5 devices due to improper file permissions, potentially exposing configuration or operational data.","url":"https://insights.sbomify.com/CVE-2024-53649/"}